09/27/2007 4.0.0.0 Q3-442 Finish and issue Version 4.0.0 Added new dialog to change size. Added reporting for design replacement size. Completed other minor fixes needed through testing. Prepared the new installation files. Version 4 was released on 9/27/2007
09/13/2007 4.0.0.2beta Q3-441 GUI: Drafting is not working for the version 4 beta -- for Microstation SE and J. file fininsha.bat was missing in the installation. Added it to fixes.
09/12/2007 4.0.0.2beta Q3-440 GUI: Change Option 'Run Refiner' to run refiner without options to remove changes. Done. Add a 'tools' option to remove refiner changes if exist.
09/12/2007 4.0.0.1beta Q3-439 GUI: Change the size of circles representing mass to have the area be eruptional to the mass (not the diameter). Done.
09/12/2007 4.0.0.1beta Q3-438 GUI: Remove 'For Use By…" on About Dialog. Add Version # on title bar. Done.
09/12/2007 4.0.0.0beta Q3-437 GUI: Prepare installation package for Version 4.0 Created two installations -- One for WinSCADS and other for PDStrudl. Program will now be installed under Program Files/WinSCADS4 -- Fixed program to make sure it runs with long file names (with spaces)
09/11/2007 4.0.0.0beta Q3-436 GUI: Errors in PreFrequency input are reported as they were in the PreStatic input. Corrected problem -- Still need to process all PreSTATIC and PreFrequency commands.
09/10/2007 3.0.216 Q3-435 GUI: Only allow to view and create/recreate drawings from the Drafting option. Add a button to update construction model on the 'Run Drafting' dialog. Completed.
09/10/2007 3.0.215 Q3-434 GUI: reorder the icons for model rotation. Completed
09/10/2007 3.0.215 Q3-433 GUI: Change the 'Drafting' icon to Microstation icon (Change the icon between MS8 and v8 icons, depending on the user's setup for Microstation. Completed as suggested.
09/04/2007 3.0.212 Q3-432 Frequency Analysis: On Frequency Analysis Report, separate mass at supports from 'Total' mass. Completed as suggested.
08/29/2007 3.0.211 Q3-431 GUI: Add warning for line load command if user specifies beam direction perpendicular to line load. Current implementation creates the beam (s) along line load direction. Also change the 'Help' document to stress that beams are created along line load. Completed as suggested.
08/29/2007 3.0.211 Q3-430 GUI: On Error Dialog, change the error message for duplicate beam numbers to point to the actual lines creating the duplicate beams (instead of pointing to the first line of floor below). Completed as suggested.
08/29/2007 3.0.211 Q3-429 GUI: Add plotting for mass specified in Frequency Analysis Added options to plot mass under tab 'Model' on 'View Attributes' Dialog.
08/23/2007 3.0.211 Q3-428 GUI: Modify the Update Construction Model Dialog to exclude the 'Run Update' and hide the checkbox for other application. Done.
08/21/2007 3.0.210 Q3-427 GUI: Update all Construction application from one menu selection without have the user to specify different options. Done. Also added a "Run Customized Construction Applications' under the 'Tools' menu option.
08/21/2007 3.0.210 Q3-426 GUI: On Design Properties tab, change 'Initial Size' to 'Design Suggested Size'. Also, add text for the initial size if it is different than the 'Design Suggested Size'. done
08/16/2007 3.0.209 Q3-425 GUI: Remove the I/O buttons from the 'RUN' dialogs. Have separate tabbed dialogs for these input/output files. Removed all I/O buttons from the Post and Construction applications. Added menu options under results as well as new Icons to view/edit these files.
08/16/2007 3.0.209 Q3-424 GUI: Allow Show/Hide DOS and Log Files on all run dialogs. Added two check buttons on all run dialogs to show/hide wither the DOS window or the Log file.
08/16/2007 3.0.209 Q3-423 GUI: Run Construction Applications should update all construction applications. Modified run dialogs. Created a separate dialog to run Refiner. Run Construction Applications now starts with options to update all applications if needed.
08/14/2007 3.0.209 Q3-422 GUI: On Run Dialog, allow separate options for Prepare Analysis for Static and Frequency. Done -- See new Analysis Run Menu. Options are changed automatically to ensure proper selections. Added options to show or hide both DOS and Log windows. Older results are removed from files prior to run to ensure that user sees a failed run.
08/14/2007 3.0.209 Q3-421 GUI: Move Pre-Frequency Input window with main window input tabs. Done. Need to add error checking later.
08/14/2007 3.0.209 Q3-420 STAAD: Log file indicates missing analysis output file after running STAAD. Corrected problem.
08/14/2007 3.0.209 Q3-419 STAAD: Staad file is not opened automatically. User has to open it. Modified program to open STAAD file automatically.
08/14/2007 3.0.209 Q3-418 STAAS Translator: Remove DOS pause for errors since users may not show the DOS window during the analysis run. Completed.
08/13/2007 3.0.208 Q3-417 GT-STRUDL FREQ: Add at end of GT-STRUDL Frequency file the following write Statement: LIST DYNAMIC MASS SUMMARY JOINTS EXISTING. Completed
08/13/2007 3.0.208 Q3-342 STAAD Tran: Needs to finish Frequency Analysis. See Jeff's email on 2/6/2007 Completed as suggested.
08/10/2007 3.0.208 Q3-416 GUI: Move Frequency Analysis with the 'Static Analysis' run and output files. Frequency Analysis now is run from the Main Run Dialog (Not the Post Analysis Dialog.
08/08/2007 3.0.208 Q3-415 GEOM: Geom Help states that input for lists goes up to column 80 on the GEOM data line, while implementation allows only up to column 78. Modified program to allow up to column 80
08/08/2007 3.0.207 Q3-341 Frequency Analysis: No self weight from vertical members, including columns -- mass is not correct. Needs to fix Predana to include this loads. Corrected program to include all members self weight and also loads applied to bracing and MISC members. Continue to check implementation.
08/02/2007 3.0.206 Q3-414 GUI: Update PDMS, Detailing and drawings when user selects the "Update Construction Model" option on the "Construction Model" dialog. The Construction Model response has been changed as follows: (1) If "Update Construction Model" is selected, Drafting, Detailing and PDMS options are also selected. (2) A new option under drafting "Update All Drawings" has been added and is selected when "Update Construction Model" is selected. (3) Un-connected Model for PDMS is now the default choice. (4) Options selections are not saved for next display of dialog if "Update Construction Model" is selected. (4) Running refiner with other applications (Drafting, Detailing and/or PDMS) has been disabled.
07/27/2007 3.0.205 Q3-413 GUI: 'Save As' option does not copy the frequency pre-analysis file (predanan.dat) Changed the program to make sure to copy 'predanan.dat' (frequency-analysis input file) from the source folder.
07/18/2007 3.0.204 Q3-412 GUI: Lengths of spliced columns were not shown correctly on the geometry properties dialog. Corrected.
07/18/2007 3.0.204 Q3-411 GUI: Columns should not have cutbacks on graphics. Supports, hanger-tops and posts would show cutbacks. Corrected graphics as stated.
07/18/2007 3.0.204 Q3-409 GUI: Graphics displays an error if user tries to splice the top of a column. GEOM is using this technique to extent top of the column upward. Modified graphics to match GEOM program.
07/16/2007 3.0.204 Q3-408 Frequency: Default frequency input file Is not added to new building files. Fixed problem. Default file is now added to newly created building folders, or with existing folder with a zero-size input file.
07/13/2007 3.0.203 Q3-407 GUI: Match GEOM rules for CQUD: QJNT must be specified prior to using it within a CQUD command. Done -- Added an error message to graphics.
07/13/2007 3.0.203 Q3-406 GUI: Correct K values displayed on graphics for 'KFAC ---- ALL'. 'KFAC --- ALL' applies only to columns within block created at the time of issuing the KFAC command. Graphics was showing that KFAC applied to all columns at the floor. Error corrected.
06/21/2007 3.0.203 Q3-405 GUI: A warning that field 12 does not have integer on the EQPT card is not caught by graphics. Added the warning
06/21/2007 3.0.203 Q3-404 Geometry & GUI: EQPT load within an open-side rectangle is not caught by graphics errors. GEOM error in this case is misleading. Corrected both program to catch the error and display same error message.
06/19/2007 3.0.202 Q3-403 GUI: Some wind Line loads may cause graphical selection not to work correctly (Wind loads are always selected for any clicking). Corrected programming logic.
06/19/2007 3.0.202 Q3-401 GUI: Horizontal line load direction on X-beams is displayed in the opposite direction. Corrected.
06/19/2007 3.0.202 Q3-400 GUI: Pressing 'F5' key from the text window to highlight a wind load on graphics does not work unless wind loads are already turned on. Corrected.
06/18/2007 3.0.202 Q3-402 GUI: Arrows are not displayed for wind line loads on beams. Also, these line loads are always drawn on the same side of beam. Added arrows and drew loads on the loaded side of the beam.
06/18/2007 3.0.201 Q3-399 GUI: Change the error message about "Load is outside closed rectangles" to Load exceeds beams limits at (specify direction). Completed as suggested
06/18/2007 3.0.201 Q3-398 GUI: Graphics is created beams not created by original GEOM. Same beams were not created by the graphics version a year ago. This happened as the results of the changes of Q3-259. Corrected the graphics to match GEOM rule: Beams can be created by the LOAD command with equal spacing as low as 3 inches (Specified on the Max-space field). However, beams cannot be created closer than 8 inches using the SPAC command.
06/18/2007 3.0.201 Q3-397 GUI: Display the hourglass right after pressing the "Run" button on the static run and construction applications dialogs. completed.
06/14/2007 3.0.201 Q3-396 GUI: Analysis running dialog and LOG File dialog do not maintain their locations and size between runs. Also, the last message for "End of Run" does not show in some cases. Corrected the displays as needed. Other memory problems were resolved.
06/13/2007 3.0.200 Q3-395 GUI: Graphical display of results from PD run is not correct -- GT results are OK. Corrected the error.= and implemented logics to speed up files processing.
06/07/2007 3.0.200 Q3-394 Drafting: Define the default location for the shape text at .33 from start of member for X- bracing and columns. Implemented as suggested -- Location for K-bracing members was also changed. Implemented for all versions of the Drafting program (Versions SE, J and V8)
06/06/2007 3.0.199 Q3-393 GUI & Detailing: Allow work-points to be placed along centerlines of beams and columns. Introduced a new GEOM command WPTS (Please see User's Manual for details).
06/04/2007 3.0.197 and 149K Q3-392 GUI: Differences may show between graphics and original GEOM when using the STRU command. Graphics skipped generating beams when a beam existed between the 'FROM' and 'TO' columns. GEOM skips the beam generation if a beam is connected to the 'TO' column (no matter what is the 'FROM' end of the beam. Graphics changed to follow same rule as GEOM.
06/01/2007 3.0.196 Q3-390 GUI: Cannot view joints and analysis elements after creating analysis model for first time. Corrected problem.
06/01/2007 3.0.196 Q3-389 Refiner: Update Refiner program to Microstation V8 Created a V8 version for the Refiner program.
05/31/2007 3.0.195 Q3-387 Drafting: Update Drafting program to Microstation V8 Created a V8 version for the drafting program. Testing is in progress.
05/25/2007 3.0.193 and 3.0.149J Q3-388 Detailing: Material Takeoff weight does not agree with values reported in DESI and analysis program. Problem shows in SI units files -- Weight is less by a ratio of 1.488164 -- factor to translate from lbs/ft to KG/Meter -- Error corrected.
05/16/2007 3.0.192 Q3-386 GUI: Clicking on white space brings properties dialog for some buildings. This took place if displacements are displayed after changing input and running "Prepare for Analysis..". Problems corrected.
05/15/2007 3.0.189 Q3-385 GUI: A second user to open a specific building model causes the first user to abort from WinSCADS. Corrected programming memory error.
05/09/2007 3.0.188 Q3-384 GUI: Some errors for area loading were not caught by Graphics error system. Corrected.
05/09/2007 3.0.188 Q3-383 GUI: Graphics column name may be different than Original GEOM name. Corrected. RCOL on top in the General Data caused to rename top of columns in slopped area. This was not done in the original program.
05/07/2007 3.0.188 Q3-382 GUI: Graphics produces some errors for missing beams on the LOAD, BLOD and BEAM commands. Graphics did not detect all beams on borders of blocks due to wrong programming logic. Error corrected.
05/07/2007 3.0.188 Q3-381 GUI: Graphics did not catch error for ft-in numbers ending with - or / (for example (-2-). Corrected to display an error message.
05/07/2007 3.0.188 Q3-380 GUI: For beams placed close to each other, Graphics may generate beams not created by original GEOM. 'Close' beams created with SI or METRIC input may be created in graphics and not within original GEOM. Close members are defined to be within 8 inches (0.667 ft). By mistakes, the close-distance variable 0.667 was multiplied twice by 0.3048 (instead of once) to convert the value to metric. Error corrected.
05/04/2007 3.0.188 Q3-379 GUI: There is a delay between reading new building data without any activity. This is a time used to clear memory. A message is now displayed indicating that memory is being cleared.
05/04/2007 3.0.188 Q3-378 GUI: Connecting a MISC member above top a column is allowed by both Graphics and original GEOM. However column is not extended producing analysis problems. Add a Graphics Error for this situation. Done.
05/03/2007 3.0.188 Q3-377 GUI: Change inactive-member color from light gray to yellow. Done
05/03/2007 3.0.188 Q3-376 GUI: the Tab key did not stop at the earthquake load field of the UWND command. Corrected.
05/03/2007 3.0.188 Q3-375 GUI: Graphics did not catch the error that a floor specified on the MISC command is not found. Graphics allowed user to specify the current floor name in the "Other Floor" on the MISC command. Original GEOM did not allow so. Fixed to match GEOM.
05/03/2007 3.0.187 Q3-374 GUI: Change the menu option title Tools->Explorer to Tools->Building-Folder Files. Completed as suggested.
05/03/2007 3.0.187 Q3-373 GUI: Graphics did not catch that a to-length of a MISC member is beyond the length of supporting member. Error is not given unless the to-length is greater than 0.2 ft from end of supporting beam. Graphics used 0.2 Meter for SI and Metric input. Corrected graphics to match original GEOM that uses 0.2 ft regardless of input unit.
05/02/2007 3.0.187 Q3-372 GUI: Recently developed Results dialog does not keep selection for load case. Corrected
05/01/2007 3.0.196 Q3-391 GUI: User interface hangs after displaying an error "Cannot allocate memory" from displaying results routine. Corrected problem,
04/30/2007 3.0.186 Q3-371 GT-Translator: Large load factors halts running GT-STRUDL. Load-factor values of the SUBCOMs larger or equal 1000 or less or equal -100 produce the problem. Corrected programming logic.
04/30/2007 3.0.186 Q3-370 GUI: Graphics is not following same rules for defining end of MISC members. Fixed error. Ends of y-misc beams were not flipped correctly to match original GEOM. Here are the rules: If the MISC member has an x-component (value > 0.01), ends are switched if the member is defined in the negative x-direction. (2) Otherwise, if the member has a y-component (value > 0.01), ends are switched if the member is defined in the negative y-direction; (3) Otherwise for vertical members ends are switched if member is defined downward.
04/17/2007 3.0.182 & 3.0.149I Q3-369 CODE_CHECKING: The command PRINT IR = TOP 10 either causes the program to halt or produces incomplete output. Corrected programming memory problem. Command would have worked fine for up to 6 top values.
04/04/2007 3.0.181 Q3-368 GUI: Clicking a member when torsion data displayed causes the program to halt. Corrected programming problem,
04/04/2007 3.0.149H Q3-367 GUI: Some menu items are not active in the user's version of program 149G. Corrected problem and issued update 149H.
03/27/2007 3.0.149G and 3.0.180 Q3-366 GUI: First Load of string loads may not show in graphics. Corrected.
03/19/2007 3.0.179 & 3.0.149G Q3-365 GUI: Beams connected to beams on raised by slope or TOS did not show connected correctly on Graphics. Corrected graphics problem.
03/18/2007 3.0.179 and 3.0149G Q3-364 GUI: NBRA beam can be any beam within the floor block. Graphics restricted it to the beam between the two columns. Corrected graphics to match original GEOM -- Any beam can be used for the NBRA supporting beam.
03/16/2007 3.0179 Q3-363 GUI: Point loads on columns without beams causes graphics error. Corrected problem.
03/16/2007 3.0.149E Q3-362 GUI: Program halts if DESI is not running for errors. Corrected as done for testing version by bypassing reading the "reaction table".
03/09/2007 3.0.179 Q3-361 GUI: Results show displacements according to "STRUDL" coordinate system. Modify to SCADS Input coordinate system. Changed as indicated.
03/08/2007 3.0.179 Q3-360 GUI: Allow to show/hide different warning messages. Remove SKIPON/SKIPOFF warning from the original GEOM file. Added a new dialog under Menu "Tools" to show/hide different categories of warnings (SKIP, Sizes, Column-Lines, Others). Removed the SKIPON/SKIPOFF warnings from the original GEOM program
03/08/2007 3.0.179 Q3-358 GUI: Difference in column elevation name (between graphics and original GEOM) may been seen when using the SLOP command. For top sloped columns, graphics used the floor below while it should be the floor above as a name for the column floor.
03/05/2007 3.0.178 & 3.0.149D Q3-356 GUI: Column line locations can be repeated on different COL/XBAY/XCOD/YBAY/YCOD commands. No warning or error messages are displayed if new location is within 0.25 ft from original location. However, graphics used the new location while original GEOM used the previous location value. Corrected graphics to use the previous value similar to original GEOM program.
03/05/2007 3.0.178 Q3-357 GUI: Fix for Blocks in Q-345 caused a warning for column without splice to be removed. Corrected problems and modified the warning message to recommend adding a splice or removing the size command.
03/02/2007 3.0.178&3.0.149D Q3-355 GUI: Graphics is not catching all overlapped beams that can cause analysis problems. Added appropriate checks and error messages.
03/01/2007 3.0.177 and 149C Q3-354 GUI: User must use Q in field 3 with area phantom load. Graphics and original GEOM behave differently for a P in field 3 and area load. Changed graphics routines to replace the P with Q to produce the same model as the original GEOM. Added an error message to warn the user.
03/01/2007 3.0.177 Q3-353 GUI: EQPT load with no opening (blank for number of legs) should create 4 beams. Graphics erratically shows 2 or 4 beams for this condition. Corrected programming error related to creating 2 or 4 beams. This error only existed in the current test version (not the user version) Problem fixed.
02/19/2007 3.0.176 Q3-352 GUI: Graphics gives warning about loaded beams are deleted while this is not true. Problem showed for same beam numbers in different blocks. Problem fixed.
02/16/2007 3.0.175 Q3-351 GUI: Column shows excluded while is should not be. This is the effect of the change in Q3-285 -- Deleting all members connecting top of columns excludes the column to match the original GEOM model. However, reconnecting beams again should remove this exclusion -- Corrected in current version
02/16/2007 3.0.175 Q3-350 GUI: Column size must be specified within the block area. Graphics did not catch this error. Error added -- The message now reads "Column not found or not within the block area".
02/15/2007 3.0.175 Q3-349 GUI: Change warning for beam intersection with an opening to indicate that beam will not carry loads from area load. Also, remove the warning for cantilevers intersecting with openings. Done
02/15/2007 3.0.175 Q3-348 GEOM: Lists (like in SIZE command) are limited to a maximum of 100 members. Increase the limit. Increased limit to 1000.
02/14/2007 3.0.174 Q3-346 GUI: Add a menu item/toolbar icon to reload the error file without reloading the building. Added a menu item under Tools to "Reload the Error File". Also added a corresponding icon on the toolbar. The item is active only if an error file exists and has been closed by user. Active error message is now colored on the error dialog. Also, user can view error message by pressing F6 (or Menu Edit/Show Error) from the text window.
02/12/2007 3.0.174 Q3-347 GUI: GEOM Help text does not show completely if the window is narrow. Show the text when the cursor is placed on the this help text. Added tooltip property to the status bar text for GEOM. If mouse cursor is placed on the text, the complete text will show in a separate window.
02/08/2007 3.0.173 Q3-345 GUI: Incorrect errors are given for graphics interface for specifying data on border of two BLOCKS. Corrected error messages.
02/07/2007 3.0.172 Q3-344 GUI: Graphics gives an error for NBRA connected to beam created on a preceding BLOCK. This should be OK if beam is on border of the two blocks. Corrected
02/06/2007 3.0.172 Q3-343 GUI & HELP: Older Version of GEOM allowed code "O2" in field 3 of the EQPT command. The number 2 to generate only 2 beams for the opening. Disable this option to prevent loading errors. Completed as suggested,
02/06/2007 3.0.171 Q3-340 GUI: Error 'Beam not found' is issued on Graphics for QJNT on a beam within block B or higher. Corrected.
02/05/2007 3.0.170 Q3-339 GUI: Show all 'CODE-CHECKING' results for controlling load combinations on graphics properties page for selected member. Completed.
02/02/2007 3.0.170 Q3-338 GEOM: GEOM gives warning or errors out if project number on HED command is not numerical. Remove warning/error since this value is not used anymore. Program now uses the project folder name. Done
02/02/2007 3.0.169 Q3-337 GUI: GEOM gives warning for unused values on 'BEAM" commands. Match warning on graphics. Done
01/30/2007 3.0.169 Q3-336 GUI: Lux and Luy values are not shown correctly on graphics when creating columns using MISC commands without other floor beams. Corrected problem.
01/30/2007 3.0.169 Q3-335 GUI: Warning messages for non-orthogonal columns without specifying UBL or KFAC only states column name without floor. Add the floor name to the message. Done.
01/25/2007 3.0.167 Q3-334 GUI: On graphics, column segment below a knee-brace member did not change its elevation name. GEOM model changes it if an active floor exists above the lower point of the knee-brace. Corrected.
01/18/2007 3.0.165 Q3-333 CODE CHECK: Critical section may show along the member (at 0.9) in cases that has no mid-span loads. Round-off routines caused the problem showing very small moments at these sections. Moments less than 0.001 K-ft have been reset to zero to eliminate this problem.
01/16/2007 3.0.165 Q3-332 GUI: Error that User Steel table is empty, while it is not. This happened for small files -- check that file is empty has been changed from 1000 bytes to 10 bytes.
12/29/2006 3.0.162 Q3-331 GUI: Add graphics for results displays. Major additions done during the month of December. Continue to debug and finish implementation.
12/12/2006 3.0.161 Q3-330 CODE-CHECKING: Correct Diagnosis label 'Lb' to 'Lamda' for LRFD code. Done.
12/11/2006 3.0.149A and 3.1.160 Q3-329 GUI: Deleted beams are not removed from the information to calculate bracing points for other beams. This can cause error in calculating the Cb design factor. Corrected.
12/11/2006 3.0.149A Q3-328 GUI: A point load at a corner of two beams should be placed on the first-created beam to match original GEOM logic. Corrected. Release with production version.
11/29/2006 3.0.155 Q3-327 GUI: Application windows (like FOUNDATIONS program) do not open the corresponding help files. Item was not completed yet. Added code to open the help files for all applications and output files.
11/29/2006 3.0.155 Q3-326 Help; Remove copyright citation text when copying from the help files. Also, fix the help for CWND (not active). Done as suggested.
11/28/2006 3.0.155 Q3-325 GUI: Arrows for horizontal point loads are always plotted in the positive direction. Negative loads should be plotted in the opposite direction. Corrected.
11/27/2006 3.0.154 Q3-324 GUI: CWIND load is not assigned the right direction for loads in x and -x directions. Corrected.
11/27/2006 3.0.154 Q3-323 GUI: Show displaced shape graphically. Added new option under Results menu to view results graphically. Added a corresponding icon on the main tool bar for results.
11/09/2006 3.0.154 Q3-322 GUI: GEOM frees out-of-plan rotation of a cantilever supported by a vertical Miscellaneous brace at a column. Graphics needs to match this modeling. Corrected graphics.
11/06/2006 3.0.153 Q3-321 User Steel Table: Correction in Q3-312 caused program to error when combining with other steel tables. Corrected error.
11/03/2006 3.0.153 Q3-320 GUI: Elevation name in filed 5 of the NBRA, KBRA and XBRA commands is not validated. Added needed error messages.
11/02/2006 3.0.152 Q3-319 GT Translator: Allow to do P-Delta analysis in more cycles within GT-STRUDL. Added new PreSTATIC command: GTS CYCLES n, where n the number of load increments. For example GTS CYCLES 3 to do the P-Delta analysis in 3 loading cycles using GT-STRUDL.
10/31/2006 3.0.151 Q3-318 FGT-Translator: For cases where P-Delta analysis to be performed, generate the GT data file to carry out a linear analysis for load cases and non-linear P-D analysis for the load combinations. Done using commands like the following: LOAD LIST ALL $$--LINEAR ANALYSIS FOR LOAD CASES: INACTIVE LOADS 51 TO 55 STIFFNESS ANALYSIS REDUCE BAND $$--NONLINEAR ANALYSIS FOR COMBINATIONS: LOAD LIST ALL INACTIVE LOADS 1 TO 50 MAXIMUM NUMBER OF CYCLES 15 NONLINEAR EFFECTS GEOMETRY ALL MEMBERS NONLINEAR ANALYSIS LOAD LIST ALL
10/31/2006 3.0.151 Q3-317 Code Check: Add strength check for bending of T-shaped sections using the LRFD code. Currently such a member is assigned a value of 100 for interaction ratio. Changed to design procedure to match flanges of w-shaped sections.
10/27/2006 3.0.150 Q3-316 GUI: On the 'Design' tab of the 'Properties' dialog, beam and column lengths are reported using the 'Output' units. All other properties are reported using the 'Input' units. Changed the 'Design' properties units to 'Input' units. Results are saved with 0.1 accuracy that can produce an error of 0.3 between actual input and displayed values from the design output.
10/27/2006 3.0.150 Q3-315 GUI: Displaying x-brace symbols displays the n-brace symbols. Corrected.
10/27/2006 3.0.150 Q3-314 AMSTL Steel Table: L3X3X5/8 had an error (-.0-.0) input in line 5. This caused error with the new FORTRAN compiler. Corrected file. Users had their files correct. These files were created by the older FORTRAN compiler.
10/27/2006 3.0.150 Q3-313 Code Check: LRFD is rejecting L-shaped sections with bending moment. A 2000 supplement has been issued by AISC to check flexure and combined stress for L-sections. Implement this specification. Implemented and documented. Still require verification before release.
10/25/2006 3.0.150 Q3-312 User Steel Table: Maximum number of allowed user sections is limited to 50. Increase it to 500. Done.
10/25/2006 3.0.150 Q3-311 User Steel Table: Add a template for user table steel file when creating new building folders. Done.
10/24/2006 3.0.149 Q3-310 GUI: Duplicate all error messages from the User Table program into the new user interface. Added error and warning messages for all input of section properties in the user table file. Checks for large or negative values still need to be added.
10/24/2006 3.0.149 Q3-309 User Steel Table: Missing property for special section causes program to halt. Also, missing B, D, tf or tw for basic section causes the program to halt. Corrected programming errors.
10/23/2006 3.0.149 Q3-308 User Steel Table: Table may not run if user section are only used without combine or attach. Corrected problem
10/23/2006 3.0.149 Q3-307 User Steel Table: Program uses older table if new input is containing errors that should have prevented the creation of the new table. Made sure to delete the "Shape.dat" and "*.nas" files prior to a re-run to insure using the newly created-data.
10/23/2006 3.0.149 Q3-306 GUI: Change the option to show 'Zero' loads to show/hide the zero loads without regard to the load type. Also fix F5 (Show graphics object from text Editor) to show the zero load in addition to created beams. Done.
10/20/2006 3.0.148 Q3-305 GUI: Users like to see location of zero specified loads since these commands generate beams. Added option of the Loads Dialog to show and hide zero loads. Users need to check this box to see the locations of zeros loads. Note that zero point and line loads are drawn without arrows.
10/20/2006 3.0.148 Q3-304 GUI: Draw smaller X's for joint marks. Done.
10/20/2006 3.0.148 Q3-303 GUI: Some column symbols are shown much larger than they should be. Members with un-specified size and do not have initial size (erased) were assigned depth and width = 1 meter for METRIC files. Changed to 0.3048 meter (1ft).
10/20/2006 3.0.148 Q3-302 GUI: TOS command does not change z-coordinate of supported qjoints/cquads or members. Corrected graphics. Users are advised not to use the TOS command without the R option. TOS of steel command without the R separates connected members and q-joints.
10/20/2006 3.0.148 Q3-301 GUI: Program unnecessarily re-reads the input when switching between construction and analysis model. Corrected.
10/20/2006 3.0.147 Q3-300 GUI: On the Show/Hide members dialog, make sure that Misc option shows and hides all MISC members (Do not consider members orientation). Done.
10/19/2006 3.0.147 Q3-299 GUI: CQUDS do not seem to be located correctly when using QJNTs together with TOS or SLOP applied to connected beams. Corrected graphics programming inconsistencies. CQUDS and QJNTS should have different construction and analysis coordinates.
10/17/2006 3.0.146 Q3-298 GUI: Error that line load cannot be supported is displayed while it should be OK. Corrected.
10/16/2006 3.0.147 Q3-296 CODE CHECK: WT, double angles and single angles are not checked correctly when b/d and tf/tw ratios are less than the limiting proportions mentioned in Appendix B of the LRFD and AS9 codes Corrected.
10/16/2006 3.0.146 Q3-297 GUI: Beams rotated by the SLOP command do not need to be checked for the input of Lux and Luy. Done.
10/16/2006 3.0.145 Q3-295 GUI: An error is displayed that number of analysis load is not equal number of specified load. Corrected problem. This happened for line loads not specified to be applied directly on top of an x or y beam (round-off problem).
10/16/2006 3.0.145 Q3-294 GUI: Check USERT input while loading the file. Added error checking for main input. Error checking for section data will be added next with a complete revision for the help file.
10/16/2006 3.0.145 Q3-293 USERT: Make sure WinSCADS is using correct units for section properties when using USERT.
 
10/16/2006 3.0.145 Q3-292 GEOM: PSHL thickness is not correct in the analysis file if output unit is different than input unit (If one is STD and the other is either METRIC or SI). The difference is 25.4 factor. Corrected programming error.
10/05/2006 3.0.145 Q3-291 GUI: Fix the DATAR display dialog activated from the Tools menu. Changes the display window to a standard output dialog with print and search capabilities. Added reactions tables to the display.
10/03/2006 3.0.144 Q3-290 Deleting members supporting other members gives an error message. Do not give this message until processing all members on command line to see if supported member was also deleted or not. Changed as suggested.
10/03/2006 3.0.144 Q3-289 GUI: Some columns may not get the same floor name as in the original GEOM program. Corrected difference. This happened as a result of round-off difference. This problem showed when connecting a MISC member to column within 1 inch from another floor.
10/03/2006 3.0.144 Q3-288 GUI: Program did not run again if window was maximized prior to exiting. Corrected error. Problem was introduced in last release 3.0.143.
09/27/2006 3.0.143 Q3--287 GUI: "SPLC ALL" command shows splices on graphics for columns starting at current floor. This should not be there. Removed splices at top of column.
09/26/2006 3.0.143 Q3-286 GUI: Minimizing and maximizing main window cause toolbars to form several rows without returning back to one row when maximizing. Need to automatically rearrange the toolbars when maximizing the window. Added a button on the View-Tool Bars menu option to re-arrange toolbars. The action of this button is automatically done by the system after maximizing the main window. Also, added a button on the view toolbar to quickly allow the user to access the toolbar dialog.
09/25/2006 3.0.142 Q3-285 GUI: See Q3-280 -- Related to deleting beams supported by a column. Old GEOM version simply excludes this column from analysis if it is a top piece. Match original GEOM. Instead of giving the error explained in Q3-280, this version will now exclude such a column. If column is really not needed, user should use the DEL or erase commands to remove it from the construction model
09/25/2006 3.0.142 Q3-284 Help &GUI: DEL command automatically deletes beams connected to columns only. It does not delete beams connected to deleted beams as stated on the Help and shown on Graphics. Corrected graphics and changed the help to read as "All members framing into the deleted column are also deleted automatically."
09/22/2006 3.0.142 Q3-283 GUI: Line load outside structure error is not reported on graphics errors window. Recent change removed this error message. Error message has been reinstated.
09/22/2006 3.0.142 Q3-282 GUI: Error that number of specified loads is not equal number of analysis loads, if specified loads are completely outside structure. Problem corrected. This error message was added earlier to catch any programming errors with loads that cause system crashes from programming errors.
09/21/2006 3.0.141 Q3-281 GUI: One error on a size command for column may produce wrong errors for all other columns listed on the command. Corrected.
09/20/2006 3.0.140 Q3-280 GUI: Deleting all beams supported by a column, deletes the column on graphics and analysis model, but keeps it on the construction model. Need a way to remove this inconsistency or warn about it. Added an error message on graphics advising the user to delete the column instead.
09/20/2006 3.0.139 Q3-279 Geometry: A zero value for the from or to length on the NBRA command creates vertical beams on connected columns. Zeros should not be allowed. Added error message and ignored input for zero values on the command.
09/13/2006 3.0.138 Q3-278 GUI: Some loads and members may be selected without clicking on these objects. Corrected.
09/13/2006 3.0.137 Q3-277 GUI: The DEL key and Delete option on the Edit menu and right-click for the text-editing are not working as expected. Corrected.
09/13/2006 3.0.137 Q3-276 GUI: Provide the user with a tool to view objects created by each one of the Geometry data lines. From the Geometry text window, the user can now locate the cursor on any line and then presses the 'F5' key; selects the Edit/Show graphics objects; or right-click and selects 'Show graphics objects'. This will display the properties dialog with all objects listed on the top window.
09/09/2006 3.0.136 Q3-275 GUI: Warning message for KFAC not provided for non-orthogonal column is displayed even if 'KFAC ALL' is provided. Corrected.
09/08/2006 3.0.136 Q3-274 GUI: Diagonal cannot be created within 8 inches of supporting beam edges. Also diagonals center must be within the block area. Changed graphics and added error messages.
09/08/2006 3.0.136 Q3-273 GUI: The 'Source' button on the 'Properties' dialog does not point to the correct line for diagonal members. Corrected.
09/07/2006 3.0.136 Q3-272 GUI: NBRA cannot be created unless supporting beam is within current block. Corrected and added an error message.
09/07/2006 3.0.136 Q3-271 GUI: Match behavior, errors and warnings from original GEOM for the 'DEL' command. Done. Columns cannot be deleted if supporting beams fm different blocks. Vertical bracing members cannot be deleted with the 'DEL' command.
09/06/2006 3.0.136 Q3-270 GUI: Match behavior, errors and warnings from original GEOM for the COL/XBAY/XCOD/YBAY/YCOD commands. - Uncreated column can be used for reference column. The system gives an error and then creates the column line at zero coordinate. - Incorrect numbers of "COD" and "BAY" items generates a warning message and then the system uses the lower value. - Corrected location problem for columns repeated on different XCOD/YCOD commands.
08/31/2006 3.0.135 Q3-269 GUI: Column base condition in graphics may not match the analysis model if FIX command is issued more than once for same column with different x and y directions. Corrected the graphics and added a note in the help document for the FIX command. Also, added a new error message if field 2 of the FIX or PIN command is not an "ALL" or blank.
08/28/2006 3.0.135 Q3-268 GUI: Fix error and warning messages related to list items on CFY, CFU, SLOP and RBEM commands. - Added warning for ignoring columns listed on BFY, BFU, RBEM SLOP or TOS commands. - Changed GEOM 'warning' to 'error' for wrong values on the CFY and CFU commands. - Graphics did not change column Fy or Fu if splices were not created prior to the CFY or CFU. Corrected problem and added warning about the splice creation.
08/21/2006 3.0.135 Q3-267 GUI & Geometry: Graphics did not catch all input errors for BEAM command when user tries to support beams on parallel beams. Added error messages like "BEAM is not perpendicular on BEAM (--). Also modified Original GEOM program to not create a beam on tips of two cantilevers on the same line.
08/15/2006 3.0.134 Q3-266 Geometry: SIZE commands with the 'TO' form may not assign the correct sizes to the specified beams if first listed beam is not found. Corrected problem and added warning messages to list those beams not found within the 'TO' list.
08/14/2006 3.0.134 Q3-265 GUI: Match errors and warnings for QJNT input given by the original GEOM program. Added error messages if a q-joint is not located on a beam or column within the current block. Also, warnings are given if both the 'From' and 'To' distances are specified on a beam (Fields 5 and 7). In addition, a warning is displayed if a 'To' distance is specified for a q-joint on a column
08/14/2006 3.0.133 Q3-264 GUI: program halts when the user switches to another window-application while the Find/Replace text dialog is displayed. Placed a work-around code to solve a 'MS-Windows' memory management problem.
08/09/2006 3.0.132 Q3-263 STEEL TABLE: MEXIC table cannot be used in USERT. USERT gives errors that data is missing. Added missing file shape.dat and fixed file 'L.DAT' at the bottom of the file.
08/09/2006 3.0.132 Q3-262 GUI: Line load command between two columns would not create beams. Error message from graphics is not given that load cannot be supported. Added error message.
08/09/2006 3.0.132 Q3-261 GUI: Load outside rectangles is not detected by the graphics if the area load is to the right of all rectangles. Also, error that length on supporting beam (on the BEAM command) is beyond the supporting beam length is not detected by the graphics routine. Corrected problem.
08/08/2006 3.0.132 Q3-260 GUI: Lux and Luy are set by the NBRA command to be equal member length - 2 ft, with a minimum value of 1 ft. This is not show on the Properties dialog of the graphics. Corrected the dialog values.
08/08/2006 3.0.132 Q3-259 Geometry: A minimum value of 2" is set for field 12 (maximum spacing) of the LOAD command. This value causes "server rectangular" errors within GEOM. Also the graphics program is creating beams with a minimum spacing of 8 inches. Changed the minimum spacing between beams for the LOAD command to 3 inches. A value less than 3 inches is changed to 3, and an error is issued.
08/06/2006 3.0.132 Q3-258 Geometry: Disallow FLOR command version with elevation and top-of-steel on fields 5 and 6 of the command. Done. Foe the FLOR command now to work, a valid elevation name must be specified in field 2. User interface, Help document and Geometry program haven been updated.
08/04/2006 3.0.132 Q3-257 GUI: UBL for k-brace members in graphics dos not match values set by GEOM. Modified graphics to set same rules of GEOM for k-brace (KBRA) members: - Set Lux = L/2-1, Luy = L-2 (min 1 ft) for longer members; - Set Lux = Luy = L-1 (min 1 ft) for shorter member. - If an "RBEM" is issued for a k-brace member, swap the values of Lux and Luy (the swap will take place if the rotation angle is between 45 and 135 only -- Earlier version of GEOM did the swap without checking the rotation angle).
08/04/2006 3.0.132 Q3-256 GUI: Change the warning for the PSHL command to error when properties are repeated for same PSHL id with different values on the two lines. Done.
08/03/2006 3.0.132 Q3-255 GUI: Fix graphics for the EQPT command to match original GEOM program. Made the following changes: - Load is ignored if negative value is specified for either the x- or y-dimension. - A zero value specified for the y-dimension is changed to be equal to the x-dimension. - A zero value specified for the x-dimension is changed to be equal to the y-dimension. - Zero values for both x- and y-dimensions creates one concentrated equipment load.
08/03/2006 3.0.132 Q3-254 GUI: Issue an error message if a SLOP command with area format has no effect on any beam. Added the following error message: Error: No beams were found entirely within the area.
08/03/2006 3.0.132 Q3-253 GUI: Column-floor name may not match original GEOM for a column affected by a SLOP command. Changed graphics-program logic.
08/02/2006 3.0.132 Q3-252 GUI: Change Error in Q3-242 regarding the "no-beams on floor", to match the behavior of the original GEOM. The message is given now for blocks or floors with no beams created.
08/02/2006 3.0.132 Q3-251 GUI: Phantom LOAD command should not create a beam at left or bottom edge if beam is not existing. Corrected Graphics. Please note that if beam exists, it will be loaded by the phantom load.
07/31/2006 3.0.131 Q3-250 GUI: On NBRA command, if invalid value for beam distances (field 9 and 10)is found, an error should be issued (not a warning) and members would not be created [to match original GEOM program]. Corrected as suggested.
07/31/2006 3.0.131 Q3-249 GUI: A wrong warning is given that load is outside rectangles. Corrected a round-off problem to avoid the warning.
07/31/2006 3.0.131 Q3-248 GUI: Warning for "No-splice" should not be given at start of a column again after a POST or Hanger-end "HEND". Removed warning and adjusted properties for the new column.
07/31/2006 3.0.131 Q3-247 GUI: TOS command for sloped members should show the members horizontal. Warning indicating that "TOS" is making member horizontal should only be given if the member was sloped by the "SLOP" command. Fixed graphics.
07/31/2006 3.0.131 Q3-246 HELP: Clarify the HELP for the MISC command when members are connected to different floor other than active. Modified the HELP page for MISC command, and changed a warning message to: Warning: Elevation in field 8 refers to a beam (in field 6) at different floor. Ignored elevation (..).
07/29/2006 3.0.130 Q3-245 GUI: Produce error messages similar to those of GEOM if ALL is used in field 2 of the "RCOL" command. If a list exists with ALL on the RCOL command, the following error is given: Error: Command ignored -- This form or RCOL is not allowed Use the following two commands instead: RCOL ALL RCOL-90 (list) If 'ALL' is specified without a list, the error is: Error: Command ignored --ALL in field 2 is not allowed.
07/29/2006 3.0.130 Q3-244 GUI: "ALL" in the list of beams for the "BFY", "BFU" and "RBEM" command is allowed. Graphics is giving an error that "ALL" is invalid beam ID. Corrected problem.
07/29/2006 3.0.130 Q3-243 GUI: Check data at end of each floor to provide same errors/warnings provided by original GEOM (Errors/Warnings labeled by WGEOM….) Added the following warnings and errors: Warning: Column (---) with non-orthogonal rotation does not have XKFAC, YKFAC, XUBL, and/or YUBL defined at above floor. Warning: Beam (---) with non-orthogonal rotation does not have XUBL, and/or YUBL defined at above floor. The later warning for beams is not reported by the original GEOM as a result of oversight when the CODE_CHECK program (SCOLD) was changed in 1995. Error: No beams on above floor(...) --This may cause analysis problems.
07/28/2006 3.0.130 Q3-242 GUI: Rotation angle given on the RCOL and RBEM commands need to be checked for valid input -- Use 90 degrees for invalid input to match original GEOM. The following error has been added: Error: Invalid rotation angle ... 90 degrees assumed.
07/28/2006 3.0.130 Q3-241 GUI: Loads should not be allowed on vertical bracing members to match with original GEOM. Added the following error message to the MISC and BLOD commands: Error: Load ignored - Loads are not allowed on vertical bracing members.
07/28/2006 3.0.130 Q3-240 GUI: Graphics did not rotate those beams at slopped roofs (SLOP command) with R in field 13. Corrected graphics and properties dialog.
07/27/2006 3.0.130 Q3-239 GEOM: R in field 13 of the SLOP command rotates supported beams automatically to be parallel to the roof. When the roof is slopped the y-direction, the generated rotation angle is the negative of what is supposed to be. Corrected error.
07/27/2006 3.0.130 Q3-238 GUI: ALL on FPM command should apply the properties for all beams. Graphics is giving an error that ALL is not acceptable. Corrected.
07/27/2006 3.0.130 Q3-237 GUI: Add missing error/warning checks for commands using List or area format. The following errors have been added: - For UBL card used in the general data, area format is not allowed. Area format is ignored. - For UBL card used in the general data, text beyond filed 3 is ignored. - Input ignored for Beams-UBL cannot be set to zero for beams. - Error: Input ignored -- Invalid Fire Proofing code. - Error: Input ignored--No beams found within specified region.
07/27/2006 3.0.130 Q3-236 GUI: Match errors for CEND with those of the Original GEOM program. Added 2 new Error messages and changed the graphical model accordingly: (1) Give Error message if a column to be created below the elevation given on a "CEND" command. Do not create the column; (2) Process a CEND on a FLOR data to match the old model, but Give and error message that analysis and model may not be correct.
07/26/2006 3.0.129 Q3-235 GUI: Graphics for NBRA is not correct if first column is the right-column of the bay (not the left column as specified in the user's manual). Corrected graphics to produce same configuration used in the analysis and drafting. Also, using a right column first, without specifying the supporting beam number will generate an error that there is no beam connecting the two columns (even if the beam exists).
07/24/2006 3.0.128 Q3-234 Drafting: Drawings with SL shapes (double angles with short-legs back to back) produce errors for missing symbols and stops displaying section names and shapes. Corrected problem.
07/24/2006 3.0.128 Q3-233 GUI: Fix memory leaks when same column-lines are created more than once. Done
07/24/2006 3.0.128 Q3-232 GUI: For cases where NORTH arrow is in X or NX directions, graphics assigns east UWND to west group and vise versa. The direction is plotted OK, Corrected error
07/15/2006 3.0.128 Q3-231 GUI: Review old GEOM and add an-implemented error checks. The Following error checks and messages have been added: Error: Hanger (xxx) TOP found at bottom floor-Changed to support-Check input. Hanger (xxx) has no HEND command. Hanger end is assumed at last floor.
06/27/2006 3.0.127 Q3-230 GUI: Rotation angles on graphics for vertical bracing members are not shown rotated according to input data. Correction done in Q3-220 caused this problem. Rotation for vertical members were skipped for both area and list commands. Corrected to skip only for area commands.
06/27/2006 3.0.127 Q3-229 Drafting: Opened drawings gets updated and then over-written by old file if saved. Also error messages are displayed for not updating drawing sheets without specifying which sheets. Corrected error messages on the output files. Error message is displayed and update is stopped if a drawing sheet is opened or file is marked as read only.
06/25/2006 3.0.126 Q3-228 Drafting: Make sure user is using latest Microstation programs after update. Made changes to make sure that Drafting and Refiner are now run with the new update (Made changes to the module names).
06/25/2006 3.0.126 Q3-227 GUI: Update Microstation Files does not copy the mdl files to the appropriate folders. Corrected the problem.
06/22/2006 3.0.125 Q3-226 Refiner: Remove option to create Pre-Drafting data file. The option is now available within the GUI on the Construction-Model Run Dialog. Refiner Menu option removed. Older version of refiner will not create the new name format for drawing files.
06/22/2006 3.0.125 Q3-225 Drafting: Automatically create drawings on documentum side and give them a unique name Modified the User Interface to create unique names for drawing sheets using building folder name, projection and copy number. The DRAW command in the drafting program has been modified to accept this change and also be compatible with older 'PreDrafting' data files.
06/16/2006 3.0.125 Q3-224 GUI: On Geometry Text window, floor text colors may change with reloading without any floor changes. Fixed problem.
06/16/2006 3.0.124 Q3-222 GUI: On Run Construction-Model Dialog, turn 'Update Model' on/off as needed (Checked when dates are red .. Otherwise, unchecked). Completed as requested.
06/15/2006 3.0.124 Q3-221 GUI: Line loads (especially created by BLOD or on slopped members) may not show in the correct position. Checked and fixed the problem. Line loads now show vertical lines on inclined members, as it should be.
06/15/2006 3.0.123 Q3-220 GUI: UBL values are not shown correctly on Graphics-properties dialogs for vertical bracing members. Corrected error. UBL (and other) area commands were applied to vertical bracing members.
06/14/2006 3.0.123 Q3-219 GUI: Create Pre-drafting File may give 'Seek' error when reading previous titles data. Fixed logic to avoid problem.
06/14/2006 3.0.123 Q3-218 SITE IDs: Update SITE IDs file. Updated and included with current program update
06/14/2006 3.0.123 Q3-217 GUI: Modify categorization of MISC members to match original GEOM version. The following rules have been implemented in graphics to match GEOM implemented definitions: If vertical difference between the two ends of MISC is less than 2 ft, it is horizontal member (X-BEAM, Y-BEAM or Horizontal Brace); Otherwise: - If the two supporting ends are beams on the same floor, it is horizontal (X-BEAM, Y-BEAM or Horizontal Brace) - If one end is a beam and the other is a column with a distance less than .001, and beam and column pieces on same floor, it is horizontal (X-BEAM, Y-BEAM or Horizontal Brace) - If both ends are supported by columns and distances are less than .001, it is horizontal (X-BEAM, Y-BEAM or Horizontal Brace); - Otherwise it is a vertical brace. IMPORTANT: X and Y BEAMS created by MISC command can support other beams created by BEAM command and is assigned properties (area commands) as if they are x or y beams). However, these MISC members are not recognized by the load command (i.e., no loads are assigned to them from the LOAD command and also, the LOAD command can create beams that may coincide with these MISC members.
06/07/2006 3.0.122 Q3-216 GUI: Column rotations are not shown correctly on graphics. An error was introduced with the Fix for Q3-199. Error removed with this version.
06/01/2006 3.0.121 Q3-215 Re-issue update 120 as 121 for users. Done with minor changes.
05/31/2006 3.0.120 Q3-214 GUI: Frequency analysis does not run. Fixed the problem.
05/30/2006 3.0.119 Q3-213 GUI: Error "ERROR * COULD NOT FIND +INTEGER IN CARD COLUMN(S) …" is displayed from old GEOM program when input data is mis-aligned. GUI does not catch this error. Introduced a new error message to be displayed when blank spaces/invalid characters are found within a data field.
05/30/2006 3.0.119 Q3-212 GUI: Error "***WARNING * COULD NOT FIND DECIMAL IN CARD COLUMN(S) .." is displayed from old GEOM program when input data is mis-aligned. GUI does not catch this error. Introduced a new error message to be displayed when blank spaces/invalid characters are found within a data field.
05/30/2006 3.0.119 Q3-211 Detailing: Weight of steel added in refiner is not included in the 'Detailing' Material List table. Modified the 'Refiner' program to include the added weight.
05/30/2006 3.0.119 Q3-210 Detailing: Material List table does not provide steel weight. Problem existed after running the 'UPDATE' program. Problem corrected.
05/27/2006 3.0.118 Q3-209 FOUNDATION: Allow user to print results for only selected columns within the 'Foundation Report' Added a new 'PRINT' command for 'FOUNDATION' program. See the help document for the 'Foundation' program to view options on how to use the command.
05/26/2006 3.0.118 Q3-208 FOUNDATION: Foundation size may be smaller than it should be in case of uplift loads. Resisting moment did nor include the uplift wind load. Added the uplift wind load when calculating the resisting moment (RM)
05/25/2006 3.0.117 Q3-207 GUI: Phantom Load Error on cantilevers did not point to the correct BLOD command. Corrected error
05/25/2006 3.0.117 Q3-206 GUI: Original GEOM does not error out if the to-length for the supporting beam exceeds the actual to-beam length with no more than 0.2 ft (2.4 inches). Modified the graphics error system to match the 0.2 tolerance for MISC members.
05/25/2006 3.0.117 Q3-204 Post-Analysis applications and Construction Application run as separate programs. Redevelop to make them integral parts of the system. Completed tasks -- Ready for testing
04/28/2006 3.0.117 Q3-203 Bring error messages from old GEOM to the new user interface. The following messages have been added: For the BLOK Command: BLOK OVERLAPS EXISTING BLOK',I2,'. COORDINATES CHANGED TO … BLOK ENCLOSED IN EXISTING BLOK .. WILL IGNORE BLOK CARD. BEAMS WERE GENERATED BEFORE FIRST BLOK CARD AND WERE LOST. For the STRU, LOAD, SLOP, DMAX, DFIX, UBL, TOS, DMIN, ERAS, RBEM,BFY, BFU and FPM Commands: INPUT IS NOT CONTAINED WITHIN BLOK AREA. PART OF INPUT IS LOST. INPUT IS OUTSIDE BLOK AREA. CARD IGNORED.
04/28/2006 3.0.117 Q3-202 GUI: Move creation of Pre-Drafting input file from 'Refiner' to the new user's graphical interface. Done. See option under Tools "Create Pre-Drafting Data File".
04/25/2006 3.0.117 Q3-201 GEOM: Error in BLOK command may cause previously-created beams to be erroneously deleted. This caused differences compared to the new graphical model. Corrected GEOM.
03/08/2006 3.0.115 Q3-200 GUI: Old version stops when reading USERT o the unit command without having data in the USERT table. New program continues giving errors for sizes not found. Modified new UI to give the same error and quit processing data after the UNIT command. Also fixed programming error within the USERT program that terminated the program pre-maturely for wrong input data.
03/06/2006 3.0.112 Q3-195 GUI: WIND command may create wrong column names. Graphics created columns where already beams exist that support the load. Problem corrected. Also, a TOS command combined with a WIND command modified column names in cases that should not. Error fixed.
03/01/2006 3.0.111 Q3-194 GUI: Numbering system for beams on graphics may be different than the original GEOM numbering. Area LOAD commands over different bays, with unaligned edges, can cause this problem. Added error messages to recommend to the user to change the one LOAD command to multiple commands.
03/01/2006 3.0.111 Q3-193 GEOM: PLOAD error is displayed by the original GEOM program indicating "Existing beams interfere with opening", although graphics interface accepts it. Original GEOM did not account for round-off when checking for interference. Corrected to allow overlap by .005 ft (1/16 in) overlap of opening with existing beams.
02/15/2006 3.0.107 Q3-192 GUI: Not all of the string loads showed on graphics for Specified loads. Line 'Analysis' loads did not show on all beams as expected to be. Corrected programming errors in the graphical interface.
02/08/2006 3.0.115 Q3-199 GUI: Graphics did not report error in column names on the RCOL command. Added error messages to the RCOL command.
02/08/2006 3.0.106 Q3-191 PD-STRUDL: program does not run if character data is used for project number. The remaining modules work. Modified the PreSTATIC program to create the data as needed by the PD-translator
02/07/2006 3.0.114 Q3-198 GUI: Column rotation angles on graphics are different than analysis angles. This happened when the command "RCOL90 ALL" is used in the general data. Graphics rotated the columns while geom (analysis) ignored the command. Fixed the graphics to issue an error message and ignore the command. Help file for RCOL has also been corrected.
02/07/2006 3.0.113 Q3-197 Graphics is not catching the error that "Loads on deleted members were deleted". GUI & GEOM: Changed the error message from an error to a warning. Also added the warning to the list of warnings displayed by the graphics.
02/07/2006 3.0.113 Q3-196 GUI: WIND load applied at a support point removes the support column on graphics . Corrected the error.
02/07/2006 3.0.105 Q3-190 PreSTATIC: program does not run if character data is used for project number. The remaining modules work. Changed the project number variable from an integer to character.
02/04/2006 3.0.105 Q3-189 GUI: The END command is supposed not be skipped over when SKIP is ON. Graphics skips the END command if the SKIP command was placed above floors data. Corrected the 'Graphics' interface to follow the original GEOM rule (END command will not be skipped)
02/04/2006 3.0.105 Q3-188 GUI: Program breaks down (with memory error) at startup when GEOM data is not complete (does not contain floor data. Corrected programming problem with opening & closing the database file (datar).
02/02/2006 3.0.104 Q3-187 GUI: DIAG command fails to produce the correct diagonal configuration (in Graphics) when opening is bounded by more the one-beam on one of the sides. Corrected problem. An incorrect assumption was made earlier in developing the graphics (Opening was assumed to be bounded by only four beams - one on each side).
02/02/2006 3.0.104 Q3-186 GUI: MISC command is giving an error message that user is trying to connect the member beyond the end of the supporting member. Corrected problem. This happened when specifying the end of the supporting member. Too small tolerance was value assumed in defining 'same point' value.
01/03/2006 3.0.103 Q3-185 GUI: Error is displayed when X/Y COD/BAY commands exceed 78 characters. Old version of GEOM accepts 79 characters. Modified the new interface to allow 79 characters
01/03/2006 3.0.103 Q3-184 GUI: Program terminates with error when applying phantom load on cantilever. Corrected programming error.
12/21/2005 3.0.102 Q3-183 Steel Tables: File shape.dat is missing from the Korean table folder, causing errors when using the 'KOREA' table in conjunction with the User Table. Added the file to the appropriate folder.
12/21/2005 3.0.102 Q3-182 GUI: MISC members are not showing on bent views. Programming error corrected that dealt with assigning a MISC member to the closest bent
12/08/2005 3.0.101 Q3-181 Detailing: Rotated beams with angles other than 90 and 270 show twisted on SDS/2. The to-end rotation was taken as alpha-180 -- This should be '-alpha'. Corrected program accordingly.
12/08/2005 3.0.100 Q3-180 GUI: Floor name for columns may differ between new version and old GEOM model for columns loaded by the "WIND" command without beams connected at the floor level. Corrected graphics to match the older GEOM model.
11/02/2005 3.0.099 Q3-179 GUI: Graphics display switches to the text input view at random. Problem was introduced in Version 3.0.90 after adding the code for showing unspecified sizes. Corrected the error.
11/02/2005 3.0.099 Q3-178 GUI: K-factors on graphics do not match those of analysis, when using KFAC ALL. Corrected in-compatibility. Graphics only changes those columns that were spliced on the floor.
10/26/2005 3.0.098 Q3-177 GUI: Separate DL and LL -- Select separately Done -- See Loads Properties sheet (Right-click on graphics window -- Select Loads tab).
10/23/2005 3.0.098 Q3-176 GUI: Fix graphics for Phantom loads applied with a "BLOD" and "DIAG" commands. Fixed.
10/19/2005 3.0.097 Q3-175 GUI: Add Columns line bubbles on bents and shorten the floor lines. Done.
10/17/2005 3.0.096 Q3-174 GUI: User interface did not display an error for phantom load on cantilevers, if load is applied using the BLOD command. Added an error message and ignored BLOD command that creates a phantom load on a cantilever.
10/17/2005 3.0.096 Q3-173 GUI: Analysis Phantom load did not show correctly on graphics when applied using a BLOD command instead of a LOAD command. Corrected graphics.
10/17/2005 3.0.096 Q3-172 GUI: Program breaks down while reading certain load commands. LAOD command caused a memory error when used for a beam in a different block together with a PHANTOM load type in fields 3. Error corrected.
10/05/2005 3.0.095 Q3-171 GUI: Graphics did not display an error message for a specified POST/HEND without starting the column/hang on the above floors. Check added to the user interface.
10/05/2005 3.0.095 Q3-170 GUI: Graphics did not display error for MISC members if 'from' or 'to' distances are exceeding the supporting beam length. Added error trap.
10/05/2005 3.0.095 Q3-169 GUI: Misc members are not shown on the proper x or y bents. Close column lines (within 8") caused this situation. Corrected programming logic to show the MISC member on the proper bent.
09/30/2005 3.0.094 Q3-168 GUI: Add Floor Lines on Bents Views. Initial implementation is done. Floor lines are added to bent views (Vertical orientation -- angle1 =90 and angle 2 = 0). Option to show/hide lines and text are added to the "Model" property page. Floor general properties are shown on properties pages (shown for selected objects).
09/20/2005 3.0.003 Q3-167 GUI: Graphics is using a default of zero for the rotation angle in field 2 of the 'RBEM' command. The default (blank value) should be 90 degrees according to the Help and original scads. Corrected.
09/16/2005 3.0.092 Q3-166 GUI & Analysis: Disallow phantom loads on cantilevers. Done and changed help to state so.
09/16/2005 3.0.091 Q3-165 GUI: Running DOS windows for unspecified-sizes and UserT is very slow on some machines. Changed programming logic to speed up running the DOS process.
09/15/2005 3.0.091 Q3-164 GUI & Analysis: Phantom load on a cantilever beam may cause loads to be lost or altered. Fixed modeling error. Use of Phantom loads on cantilevers should be checked to assure WinSCADS is creating the desired loading pattern.
08/31/2005 3.0.090 Q3-163 HELP: Line Load command contains wrong units for loads -- Change units from load to load per unit length. Done.
08/31/2005 3.0.090 Q3-162 Need to show size ( Scads generated size (now not specified) scold shown in tab, desi not shown at all. Change un-sized member color to light blue similar to the PLOT program (Use Members Dialog to turn on/off) Implemented. A check box added to the 'Model' page to turn Specified / Unspecified Size Colors on and off. This also shows the DESI sizes or sets the Size to 'No-size'. It also changes the sizes on the property page. When button is checked, GEOM and DESI are run automatically when GEOM is changed.
08/29/2005 3.0.089 Q3-161 CODE-CHECK. LRFD design output does not show IR = 0 value for cases with P, Mx and My = 0. Fixed the error.
08/18/2005 3.0.089 Q3-160 REPORTS: Modify the CODE-CHECK report for material list to differentiate between new and existing steel. List moved to the 'Detailing' program in order to exclude the erased members and report the actual construction members. Run the 'Detailing' program and look at the 'Output' report to see the different material listings. Different lists are generated for new and existing steel.
08/17/2005 3.0.086 Q3-159 GUI: On the EQPT command, equal values for x and y dimensions should create a circular configuration and not load pairs (to match original GEOM format). Modified graphics.
08/16/2005 3.0.085 Q3-158 GUI: Graphical interface displays an error for a value of zero in field 2 of the "TOS" command. Zero is an acceptable value. Removed error message.
08/15/2005 3.0.084 Q3-157 GUI: Command line for XBAY, XCOD, YBAY and YCOD is limited to 78 characters. Errors should be displayed when user exceeds this limit. Program should only use the first 78 characters of the command to match the original GEOM input format. Implemented as suggested.
08/15/2005 3.0.083 Q3-156 GUI: A HANG command preceded by a POST command produced and error -- Should work without error. Corrected the 'graphics' error.
08/15/2005 3.0.083 Q3-155 GUI: Graphics allowed HANG command on a column that already started on a the floor above. This should not be allowed similar to the SUPPort command. Corrected.
08/11/2005 3.0.083 Q3-154 GUI: Add an option to gray-out existing members. Added a 'check' button on the 'Model' window of the 'View Attributes' dialog, to gray-out existing steel members. For designed-members color, overstressed members are colored orange (vs. red for new steel members).
08/10/2005 3.0.082 Q3-152 GUI: Correct work-points (member ends) on Graphics for vertical bracing members to match the PDMS locations. Vertical bracing members going to top of a beam should connect at TOS (not bottom of the beam) -- Corrected logic.
08/09/2005 3.0.082 Q3-153 GUI: Symbols on metric files are not to scale. Graphic sizes needed to be reduced by a factor 0.3048. Also, symbols maximum length has been multiplied by this factor to show a maximum length of symbol equals to 2 ft.
08/08/2005 3.0.081 Q3-151 GUI: Vertical XBRA may divide the connected columns into extra pieces on the graphics window. Programming error corrected.
07/29/2005 3.0.080 Q3-150 GUI: For input/output windows, system should remember location of cursor to use for next session, similar to GEOM input. Cursor location is now remembered for all input windows (PreSTATIC and User Table). Same behavior is also now implemented for all output views/windows (Results, Steel Tables and Log File). Also, last activated tab will be shown when reopening a window.
07/27/2005 3.0.080 Q3-149 GUI: Add "Checking Procedure & Log File" in a new Tabbed window activated from Tools menu Completed as requested.
07/22/2005 3.0.079 Q3-148 GUI: Intersecting X and Y beams need to be flagged as warnings to match original GEOM program. Warning messages are now issued if an X beam intersects a Y beam.
07/21/2005 3.0.079 Q3-147 GUI: MISC members created as X- or Y-beams with same numbers as other beams should not ignored, but created, to match old GEOM. Done. An error message is produced for duplicate members.
07/21/2005 3.0.079 Q3-146 GEOM: GEOM program breaks down with memory access violation error if a beam cannot be located within a rectangle. Fixed the problem by issuing an error message and then continuing the execution.
07/18/2005 3.0.078 Q3-145 GUI: MISC members connected between beams on same floor should be marked as H-X-BRACE to match original GEOM model and to keep the TOS of these members with floor beams. Corrected.
07/18/2005 3.0.078 Q3-144 GUI: Default beam direction (field 3) on the POST, HANG and SUPP commands is shortest beam to create. New graphics interface has set the default as 'X'. Default (blank value in field 3) of the PSOT, HANG and SUPP commands has been changed to create the shortest beam instead of an X-beam to match the original GEOM model.
07/18/2005 3.0.078 Q3-143 GUI: Hangers should not have beams connected to it. Graphics errors did not catch this situation. Added the error message, and ignored the HANG command if beams are already connected to the specified column.
07/18/2005 3.0.078 Q3-142 GUI: Specifying "HEND" without "HANG" command on upper floor is not caught by the new user interface errors. Added an error message and ignored the "HEND" command to match the original GEOM model.
06/28/2005 3.0.077 Q3-141 GUI: Print quality is low; printed copies are not to scale after changing to landscape. Blank pages are produced for landscape printing. Fixed above problems, and added a new menu item (Graphics Print Quality) under the File Menu. The new menu option can be used to set the printed copy quality -- A range from draft/fast to final/slow.
06/23/2005 3.0.076 Q3-140 GUI: Column sizes displayed on the graphics window may not be correct around splices. Corrected a programming logic. Also made changes to display the splice with the adjacent column piece.
06/15/2005 3.0.075 Q3-139 GUI: Finish Q3-135 and Q3-136 items (Draw symbols and shapes). Completed.
06/13/2005 3.0.075 Q3-138 GUI: Program halts after minimizing the application to use another application/program. Tabs on top of windows had a routine trying to update the tabs using a timer function. Fixed the problem by eliminating the update if tabs are not displayed on the screen.
06/08/2005 3.0.073a Q3-137 UPDATE: PDMS file may not contain refiner changes. Update program does not include refiner changes if number of members exceeds 5,000 and UPDATE is run after making the refiner changes. Limit has been increased to 10,000 and error message has been added to be displayed when the limit is exceeded.
05/26/2005 3.0.074 Q3-136 GUI: Add partial symbols Implemented for all members except vertical braces -- Work is continuing.
05/26/2005 3.0.074 Q3-135 GUI: Draw correct members/columns orientation instead of just a an I-shape Implemented for all members except vertical braces -- Work is continuing.
05/24/2005 3.0.117 Q3-205 GEOM: Rectangle errors are showing that did not show in earlier versions of GEOM. Correction in Q3-193 (Version 3.0.108) caused the error. Fixed the code to eliminate the errors.
05/23/2005 3.0.074 Q3-134 GUI: MISC member on a floor between two columns is categorized as horizontal X-brace within the construction model (old GEOM). Need to change the category within the new Graphics display. done.
05/13/2005 3.0.073 Q3-133 GUI: Column piece under NBRA member has different floor names on graphics and Code Check input data. Modified graphics to match original data when using NBRA.
05/11/2005 3.0.072 Q3-132 GUI: Users are unable to select elements within the graphics display when text for building loads are displayed. Text for building line loads was not plotted correctly causing a memory problem. Corrected program to fix the problem.
05/09/2005 3.0.072 Q3-131 PreSTATIC: Hanger bottom element is not assigned the proper elevation in Code Check input. This caused the hanger bottom element to show grayed in graphics. Fixed Pedana.exe program.
05/04/2005 3.0.071 Q3-130 GUI: Line loads do not show on x-bents; load values are printed more than once on y-line loads; and text does not show for analysis line loads. Fixed program to resolve these problems.
05/03/2005 3.0.071 Q3-129 GUI: Program sometimes breaks and terminates when reloading or opening a new building file. Fixed tabs refresh problem that was causing the break down.
05/03/2005 3.0.071 Q3-128 GUI: "No-Size" is shown on the Graphics where a size should be shown. Display of the warning message "Size or Rotation change w/o a splice" resulted in ignoring the sizes for the remaining columns within the floor, and subsequent floors. A programming error was corrected.
04/29/2005 3.0.070 Q3-127 GUI: Correct graphics disappearance/distortion and graphics printing Adjusted the display and refresh sequences of drawings to avoid problems with distortion/disappearance of graphics. Corrected errors related to scaling of text for printing.
04/29/2005 3.0.070 Q3-126 GUI: Add north arrow in graphics- next to axis Added the arrow on graphics. Also, added an option to show/hide the north arrow and/or its text on model property page
04/28/2005 3.0.069 Q3-125 GUI: Program breaks when creating a hanger supported by a new beam, when column had been created and ended earlier. Fixed programming error within the new graphics.
04/13/2005 3.0.068 Q3-124 GEOM: Change the message "BEAM/COLUMN not found in the SIZE and SAME command from ERROR to WARNING in the old GEOM output to match the new Graphics program. Done.
04/13/2005 3.0.068 Q3-123 GUI: Error window is not displayed in case of PreSTATIC errors and no GEOM errors. Fixed problem.
04/04/2005 3.0.067 Q3-122 GUI: Rapid clicking on graphics window causes distortion or disappearance of graphical model. Corrected program to prevent object selection together with model rendering at same time.
03/29/2005 3.0.066 Q3-121 GUI: Line load outside of beams area does not create error message, similar to the original GEOM program. Added the error message.
03/28/2005 3.0.065 Q3-120 GEOM: Allow user to input distributed loads on columns. A test version of new command CWND has been implemented. Users should not use this command for production yet (until final release). Currently, the columns are still not checked for stresses along the entire length (only at end points of columns).
03/25/2005 3.0.065 Q3-119 GUI: Program halts when reading data, returning error "Invalid Arguments". This took place if data included LOAD command line with errors. Program was trying generate analysis loads instead of quitting this command. Corrected logic.
03/10/2005 3.0.064 Q3-118 GUI: SUPP command cannot be used unless above column segment is posted. Graphics model did not check for this condition. Added the check and issued an error for this condition.
03/09/2005 3.0.064 Q3-117 GUI: Graphical model did not create a column for MISC command connecting to a column. Old GEOM did. Corrected graphics to match old GEOM.
03/09/2005 3.0.064 Q3-116 GUI: Graphics is not disallowing connecting beams to support columns. Added the check and prevented connecting beams to support columns to match old program.
03/09/2005 3.0.064 Q3-115 GUI: Graphics did not check for wrong values on beam commands, when connecting beams between a column and a beam and specifying the distance on the supporting beam. Corrected the problem to match old program. If the "to" and the "from" locations are not within 0.01, a message like "X beam has y dimension" is displayed, and input is ignored.
03/08/2005 3.0.063 Q3-114 Post Processing: Remove checking for MicroStation from "Post Processing" program. Done.
03/03/2005 3.0.062 Q3-113 GUI: Properties values for Equipment Analysis Load are not correct. Fixed programming logic.
03/03/2005 3.0.062 Q3-112 Steel Table: Ry for Section H150X75X5.5X9.5 in the Korean table is incorrect (6.12 instead of 1.62). Corrected error.
03/03/2005 3.0.061 Q3-111 GUI: Specified loads on Diagonals are not shown on the correct positions in the Graphics window. Corrected a programming logic.
03/01/2005 3.0.060 Q3-110 GUI: User interface checks for interference of X/Y BEAMS and MISC members. To match original GEOM, this check should be eliminated. Eliminated the interference checks if one of the members is created by MISC. Note that a MISC member created in the x or y directions is still classified as X or Y beam for loading and properties.
02/21/2005 3.0.059 Q3-109 GUI: Geom message that a fix command for hangers (columns) had a T in field 3 did not show in graphics Added the warning to the Graphical User Interface.
02/21/2005 3.0.059 Q3-108 GUI: Last few changes for area load created wrong warnings that load is outside rectangles. Fixed a programming logic.
02/21/2005 3.0.058 Q3-106 GUI: Graphics may show extra beam(s) for area loads at edge (Similar to Q3-101 and Q3-104) Fixed special cases in graphics related to loading special cases of rectangles loaded by the area LOAD command.
02/15/2005 3.0.057 Q3-105 Analysis loads generated by area load command, and column point loads, did not show accurately in Graphics. Corrected graphics programming logics.
02/07/2005 3.0.056 Q3-104 GUI: Edge beams were not completely fixed under Q3-101. Beams at end of area load commands are generated if rectangular is closed. Beams are generated if lower rectangular is opened from the right side for x-beams, and top for y-beams. Corrected to match original GEOM generated models.
02/04/2005 3.0.056 Q3-103 GUI: Analysis loads are not showing on Graphics (but generated for analysis) if part of the load is outside the floor area. Fixed to match the generated analysis loads.
02/02/2005 3.0.055 Q3-102 GUI: An error is displayed for the POST command stating that beam number must be specified in field 2. Old version of program did not produce this error. Existing beam in this case was not right under the post. Changed the program to not display the error if existing beam is within 1" from the column.
02/02/2005 3.0.055 Q3-101 GUI: Graphics may show extra beam(s) for area loads at edge. Corrected graphics.
02/01/2005 3.0.054 Q3-100 FOUNDATION: Foundation programs does not run on some machines without error messages. Program was trying to create a file (fort.4) on C:\ drive. Problem showed up if user was not allowed to write to main folder of C. Creating this file was removed in Version 3.0.54.
02/01/2005 3.0.054 Q3-099 GUI: Error Message "Beam cannot be created to support load. - Orthogonal beams do not exist" is not clear. Changed the message to "Beam cannot be created to support load.- No beams/columns to support new beam".
02/01/2005 3.0.054 Q3-098 GUI: Error is displayed that BLOD load location is beyond beam length, when load is placed at end of beam. Fixed programming error related to adding tolerance instead of subtracting it.
01/31/2005 3.0.053 Q3-097 HELP: GEOM and PreAnalysis Help files need to be updated to add details for the FIX, PIN and CONNECT commands. Done.
01/31/2005 3.0.053 Q3-096 GUI: Graphics for column base fixities do not match generated analysis model. PIN and FIX commands apply only to bases if placed within the last floor. Previous versions of graphics considered the commands if placed anywhere within the file. Problem corrected.
01/21/2005 3.0.058 Q3-107 GUI: Errors on LOAD command (From shifted data fields) did not show on new user interface. Corrected to display errors if data fields contain in-between spaces.
01/13/2005 3.0.052 Q3-094 Geometry: GEOM breaks down in point routine for wrong input. Fixed problem by issuing a warning and letting the program continue.
01/11/2005 3.0.052 Q3-095 Code Check: Produce documentation to the current WinSCADS-LRFD implementation. The document "WinSCADS_LRFD_Implementaion.pdf" has been completed to provide the requested details. Contact WinSCADS support for copy of the document.
01/11/2005 3.0.052 Q3-093 Geometry: User can not override default Lu for x-brace members, using the UBL command. PreStatic program "predana.exe" has been overriding the user UBL value for x-brace members. Program changed to apply the user's UBL value.
12/20/2004 3.0.050 Q3-091 GUI: Program may hang up when creating overlapping beams. Program went into infinite loop as a result of creating overlapping beams followed by an area load within the limits of these overlapping beams. Programming logic has been fixed to correct this problem. Also, warnings for overlapping beams were changed to "ERROR" messages.
12/15/2004 3.0.049 Q3-090 ANALYSIS: GT-STRUDL does not complete successfully when number of members exceeds 12,000. Fixed FORTRAN dimensioning limit in the binary translation program "gts2nas"
12/14/2004 3.0.049 Q3-089 STEEL TABLES: Fix errors on the TIWAN steel table. Corrected the WC dat file, and regenerated the table.
12/13/2004 3.0.048 Q3-088 GUI: Program crashes on some machines when clicking on the graphics window. Corrected a problem with OpenGL related to plotting selected text.
12/13/2004 3.0.047 Q3-087 GUI: check and Fix memory leaks to avoid program crashes. Several memory leaks fixed.
12/12/2004 3.0.047 Q3-086 STEEL TABLES: Update the Taiwan Table with emailed data file. Done
12/06/2004 3.0.046 Q3-085 STEEL TABLES: Add a new Taiwanese steel table. Added the table to replace current TIWAN table. The previous table has been renamed to "TWNOL".
11/22/2004 3.0.046 Q3-084 GUI & GEOM: Column names can exceed 8 characters using column lines names. However, "Code Check" input/output uses only the first 8 characters. This may cause graphics and reporting errors. Added a warning message to indicate a limit of 8-characters column names to avoid graphics and analysis problems.
11/22/2004 3.0.046 Q3-083 GUI: Hanger end may not show on the correct level. Corrected a programming error related to displaying the hanger end on the graphical model.
11/19/2004 3.0.045 Q3-082 GUI: If NBRA members cross each other, GUI produces an error and connects braces at mid point of beam. Fixed the error to show the NBRA members correctly.
11/19/2004 3.0.045 Q3-081 GUI: Round-off errors may produce error from the BLOD command indicating the load extends beyond end of beam. Fixed problem
11/19/2004 3.0.045 Q3-080 GUI: In old version of program, MISC members in the x-direction are handled as (and labeled) as X-BEAMS. Same is true for MISC members in the Y-Direction. Graphics model did not follow this rule creating possible discrepancies with the LAOD command. Fixed the difference to match the old version. Accordingly, some MISC members may be labeled as X or Y beams.
11/10/2004 3.0.044 Q3-079 PreSTATIC: PreDANA module does not run for large-size building models. Increased memory allocation for DESI module -- DESI ran without creating complete reaction database, causing PreDANA to halt.
11/02/2004 3.0.043 Q3-078 CODE CHECK: SCOLD module doe not complete successfully for large-size buildings. Increased memory allocation for the SCOLD module.
10/29/2004 3.0.042 Q3-077 GUI: Properties Dialog does not show on the same location after closing and re-opening. Fixed programming logic.
10/29/2004 3.0.042 Q3-076 GUI: Graphical model beam numbers do no match old GEOM numbers. Old version did not set beam numbers in rectangles in uniform order. Closed rectangles get numbered before opened ones. Modified graphical model to match old GEOM rules.
10/19/2004 3.0.041 Q3-075 GUI: Graphical model may disappear and cannot be restored, when "Fit Display" is used. Fixed scaling errors caused by empty displays.
10/18/2004 3.0.041 Q3-074 User Table: Properties for SP sections with more than 6 digits produce errors. Also, program is expecting values for k (Should not request such info). Fixed formatting problems, and corrected required data for SP sections.
10/12/2004 3.0.040 Q3-073 GUI: "Open", "New" and "Save As" dialog do not show all boxes when user sets screen font to 'Large' size. Corrected problem.
09/30/2004 3.0.038 Q3-072 GUI: Text disappears on the graphics view when updating. Fixed programming logic for OpenGL to ensure that text will always show when requested.
09/29/2004 3.0.038 Q3-071 GUI: Load locations are not correct on sloped beams and floors Fixed z-locations for point loads, line loads, wind/earthquake loads, and equipment loads for both specified and analysis loads.
09/25/2004 3.0.038 Q3-069 GUI: Column pieces below "existing" pieces did not show as "existing" (The way it should be as long no splice or other size command is specified). Corrected display error.
09/21/2004 3.0.037 Q3-068 GUI: ERASE A6 A5 A4 A3 B6 B5 B4 B3 C6 C5 C4 D6 D5 D4 D6 D5 D4 Should it check for duplicate or just ignore? not sure what old does. No change - duplicate just ignored, since removing it has no effect on results. This is the same as re-specifying same property (like size, pin, fix, ubl, etc.)
09/20/2004 3.0.037 Q3-067 GUI: Zoom loses picture on iso , center not correct, and text not in window (I.e. size of beams) Corrected Zoom In, Zoom Out, Zoom Factor, and Zoom Window to center the display. Also added another zoom Option 'Zoom Center'. The user can use this button to specify a point to be the center of display.
09/20/2004 3.0.037 Q3-066 Code Check: At end of Code Check Report, load combination names are not displayed. Instead the word "LOADCOMB" is displayed. Corrected to display the actual load combination name.
09/08/2004 3.0.036 Q3-065 PreSTATIC: "Analysis and design" process does not run for more than 99 load combinations. Increased allowed number of combinations from 99 to 200. This affected the PreSTATIC, Code Check, Drift and Forces modules. Note: A comma should not be used in the SCOM label, when using the PD-STRUDL analysis
09/08/2004 3.0.035 Q3-064 FOUNDATION: Error in SCOM command reporting that the last subcase is not valid. A bad character was being added at the end of the combination string, when the string length exceeded 74 characters. Fixed programming error with the 'FOUNDATION' program.
09/07/2004 3.0.034 Q3-063 GUI: Misc horz loads do not show up in bents, They will show up if you select the bent and each floor Point building and misc loads were not assigned bents. Fixed error to show these point loads when selecting the corresponding bent.
09/03/2004 3.0.034 Q3-062 GUI: Not checking field 3 for invalid data, field 4 Valid member numbers or columns in the ERAS command. Added error checking for the ERAS command.
09/03/2004 3.0.034 Q3-061 GUI: Need to pick up the following error/warning 499 DFIX 10 A3 A4 A5 A6B3 E4 E6 B4 B5 B6 C4 C6 D5 D6 E5 C5 D4 ***WARNING * COULD NOT FIND WORD IN CARD COLUMN(S) 20-23 Error is displayed as "A6B3" is invalid column name
09/03/2004 3.0.034 Q3-060 GUI: Need to pick up the following error/warning COLUMN A6 ALREADY HAS AN INPUT SIZE. SIZE REQUEST IGNORED Added the error message. Please note that columns cannot be resized on same floor -- beams can.
08/25/2004 3.0.033 Q3-059 GUI: Column rotation may not show correctly on graphics for columns supporting sloped beams. Fixed error.
08/24/2004 3.0.032 Q3-058 GUI: 'SIZE SHAPE' command caused the program to hang. Corrected a programming logic.
08/18/2004 3.0.031 Q3-057 GUI: No error message is produced for a negative load length on the LOAD command. Modified program to produce the error message.
08/18/2004 3.0.031 Q3-056 GUI: An interference message for non-interfering beams is displayed. Message was produced for members interfering on same floor without looking at the z-coordinates. Fixed program to check the z-coordinate to make sure that message is not produced if a TOS command was used for one or both beams.
08/18/2004 3.0.031 Q3-055 GUI: MISC member with a load specified on same card produces an error that load extends beyond beam length. Round-off causes this error. Fixed problem by rounding down the value of the load length.
08/18/2004 3.0.031 Q3-054 GUI: No 'UNIT' command on the second line is not caught as an error. Modified to produce an error if the 2nd line is not a UNIT command.
08/16/2004 3.0.030 Q3-053 GUI/GEOM: Large old file is not running. Various changes were made to get the building file running. Fix: LOAD card for openings w/o specifying direction code 'X'/'Y' sets the secondary beams on the shorter distance.
08/09/2004 3.0.029 Q3-052 GUI: TOS value on the ELEV command cannot be '0-0' inch (to match old GEOM). Use 0 only. GEOM ignores the input and uses the default of -4" instead. GUI modified to produce the error, and set the value to the default.
08/06/2004 3.0.029 Q3-051 GUI: BLOD point loads may not show on the correct location graphically. Loads did not show correctly when applied on y-beams. Error corrected.
08/05/2004 3.0.028 Q3-050 GUI: User interface is not catching errors related to interference of beams. Added warning related to interference of beams if an x or y beam is closer than 8" from another beam.
07/30/2004 3.0.027 Q3-049 CODE CHECK: For LRFD design, if P/PE exceeds 1, the system sets My either to 1E+10 or 2E+10 as a workaround to fail the member. Modified the program to display the calculated Mx and My.
07/30/2004 3.0.027 Q3-048 HELP: TOS command can take elevation name in field 2 instead of the relative distance. Current help file does not specify this. Modified help file.
07/30/2004 3.0.027 Q3-047 HELP: Line and Area Phantom Loads can be specified with a letter Q in field 3 of the Load command (Not using P as specified in current Help GEOM file) Fixed GEOM Help file.
07/29/2004 3.0.026 Q3-046 GUI: Arrangement of beams created by WinSCADS3 differ than WinSCADS2. Fixed difference. Problem may happen if load area covered more than one bay with edge of loaded area going through partial bay areas.
07/27/2004 3.0.025 Q3-045 GUI: Specified user table in GEOM, but deleted data in user table. Didn't catch error in new program. Modified program to display the error(s). Also changed the program to make sure that PreAnalysis program are marked to run when steel table is modified.
07/27/2004 3.0.025 Q3-044 GEOM: program halts with memory error in module PLBEMS. Due to input and round off errors, module was calculating a square root of negative number. Problem fixed by issuing an error message for this beam, and skipping the calculation for the related beam.
07/27/2004 3.0.025 Q3-043 GUI: Graphics may not show correct column names when SLOP command is used. Corrected special cases that change the column floor name when sloping beams.
07/23/2004 3.0.025 Q3-042 Geometry: Catch duplicate columns in G&L COL commands A warning is being issued when loading the GEOM file, if column lines coincide. User must turn "Show Warnings" on, to see this warning. A duplicate column line in the STRU command is caught in the 'GUI' as an error indicating invalid column line name. GEOM program was also modified to ignore the repeated column line and eliminate the duplicate columns that were previously created without an error.
07/22/2004 3.0.025 Q3-041 Foundation: A wind/earthquake sub-combination is ignored for a column if the wind/earthquake axial load is exactly zero Fixed problem.
07/16/2004 3.0.024 Q3-040 GUI: "String" LOADS do not create all beams, if errors found while creating one of the beams. Old version skips the wrong beam, issue an error, and then continue creating the remaining beams. Modified the program to match the older version.
07/16/2004 3.0.024 Q3-039 GUI: Error message is not displayed for missing CODE in the UNIT command. Error message added.
07/16/2004 3.0.024 Q3-038 GUI: Columns segments are overlapping, with some columns extending to the lower level of the building. This happened when point load is applied at the column location. Fixed the problem.
07/16/2004 3.0.024 Q3-037 GUI: Displaying some characters on screen causes memory errors. Fixed problem -- Problem took place when printed special characters not contained in the 256 ASCII characters.
07/15/2004 3.0.024 Q3-036 GUI: UBL = 0 is allowed -- Need to remove error message for this case. Done.
07/14/2004 3.0.024 Q3-035 GUI: String Load with SPAC command did not create the first beam in Graphics. Fixed the problem
07/13/2004 3.0.023 Q3-034 GUI: An error with the LOAD command, followed by a SPAC command causes memory error. Fixed programming logic to ignore the SPAC command that follows a wrong LOAD command
07/06/2004 3.0.021 Q3-033 GUI: CFY & CFU produce error messages that Column does not exist (not produced by the older version). CFU & CFY insert splices at 1.5 above floor level, if one does not exist. Fixed WinSCADS3 to reproduce this behavior.
06/30/2004 3.0.021 Q3-032 GUI: Error is displayed for the command UBL ALL (ALL is not valid). Old version allows this input. Corrected problem. Also a blank value in fields 3 of the UBL command was taken as XY. Corrected to use the default as 'Y' for beams, XY for columns (see help file)
06/30/2004 3.0.020 Q3-031 GUI: Posts /Hangers /Supports error is not displayed, if supporting beam is not directly under/above the column. This error message is displayed in PreSTATIC run in the old version of the program. Corrected program to check for this condition, and to display the error message.
06/30/2004 3.0.020 Q3-030 GUI: Beams coincided with other existing beams were not flagged in the error messages. Added needed error messages.
06/29/2004 3.0.020 Q3-029 GUI: Wrong beam/column IDs within the DELete command are not caught. Corrected to produce an error message for non-existing members within the DELete command
06/29/2004 3.0.020 Q3-028 GUI: New version does not create all beams with area LOAD command when load border is within 8" from the edge beam. Corrected problem.
06/25/2004 3.0.020 Q3-027 GUI: XCD, YCOD, XBAY, YBAY processed values in fields 2 and 3 as if they were entered in field 4. This would can cause problems with analysis and PDMS models. Issued error and stopped processing if the command included values in fields 2 and/or 3.
06/21/2004 3.0.020 Q3-026 Drafting: Drawing on column schedules does not fit sheet when top floor is sloped. Also size was wrong Fixed column schedule to scale according to the highest column, not the top floor. Size needs to be included on the proper level.
06/18/2004 3.0.020 Q3-025 GUI: unable to select IR- has a problem knowing the file has changed Fixed problem.
06/14/2004 3.0.020 Q3-024 GUI: ERAS is not checking for valid input Program did not check for valid beam/column ID. Corrected problem.
06/10/2004 3.0.019 Q3-023 GUI: Columns did not show up in graphics if Column line name exceeded 4 characters. Corrected problem.
06/01/2004 3.0.019 Q3-022 GUI: For SLOP command with area specification, edge beam may not get sloped similar to the old program due to a difference in the round-off used. Changed the round-off accuracy from .001 to .0001 for the SLOP command, to match the setting in the old program (WinSCADS)
05/21/2004 3.0.018 Q3-021 GUI: Graphics did not change the end location of Posts that end on beams with different z-coordinates for construction and analysis models (When TOS is used with R in field 3) Corrected the problem
05/21/2004 3.0.018 Q3-020 GUI: In a few cases, Horizontal Xbrace may not show correctly in graphics and may not show supporting column pieces Corrected problem.
05/21/2004 3.0.018 Q3-019 GUI: sloped floor may produce errors when running PreSTATIC. Errors are not caught in new user interface. Fixed the new user interface to catch and display the error prior to running PreSTATIC.
05/21/2004 3.0.018 Q3-018 GEOM: QJNTS on sloped beams do not move with beam causing PreSTATIC errors or wrong analysis members. Modified the Geometry program to move the QJNTS located on sloped beams to the proper location. Fixed the User Interface to match this change.
05/13/2004 3.0.017 Q3-017 GUI: Catch errors displayed by WinSCADS version. Modified new program to: (1) In BEAM command, cantilever length cannot be -ve. For -ve values, issue a warning and use the positive value. (2) Issue a warning when area loads are outside closed rectangles. (3) Error is given if you connect to a beam beyond its length (even if there is a beam that can support the beam)
05/12/2004 3.0.017 Q3-016 GUI: A change in the previous version caused the first line of GEOM file to show incorrectly, when reloading the file. Corrected problem.
05/10/2004 3.0.016 Q3-015 GUI: Graphics window does not show correct column names when SLOP command is used. Corrected special cases that change the column floor name when sloping beams with the list form.
05/07/2004 3.0.015 Q3-014 GUI: Memory error is displayed when reloading file. Fixed programming error trying to delete a dialog twice from the system.
04/30/2004 3.0.014 Q3-013 GUI: Printing plots text is not readable. Fixed the problem. Also, Added option "Font" on the File Menu to change the Graphics text font on screen and for printer. Also options are added to change the text font for input windows and results windows.
04/30/2004 3.0.014 Q3-012 GUI: The option to print results is not working. Completed the program. Printout can now be produced for all window text or selected text. Added "Print" icon on the tool bar. Also fixed the input printout for "Selected" text (Was not working in earlier versions).
04/30/2004 3.0.014 Q3-011 CODE CHECK: Floors with no members produce corrupted addsize file. Error found and corrected within the code check program. Block letter was not set to 'A' when beams were not found within a floor.
04/23/2004 3.0.010 Q3-010 GUI: Memory Abort problem when reading column-lines commands. Found and corrected memory allocation error. The error may occur when referencing a column-line several times in different XCOD or YCOD commands.
03/22/2004 3.0.009 Q3-009 GUI: Memory errors have been experienced by users on different machines, when reloading files. Reviewed and debugged the software and corrected a few possible sources of error. Issued several releases with the last being 3.0.9.
02/18/2004 3.0.004 Q3-008 GUI: Limit options to look for hardware key to the following two options: (1) Local; (2) Server with specified server name. Done. See Tools/Options Dialog.
02/16/2004 3.0.003 Q3-006 GUI: Error message is displayed for duplicate members in the new version and not in the old version of the program. DEL command was used to delete the first duplicate member. To match old-version of program, error is now delayed until end of reading all of floor commands.
02/16/2004 3.0.003 Q3-005 GUI: Error is displayed that CQUD cannot create a column, when the column is created in a command following the CQUD command. Corrected to match old program.
02/16/2004 3.0.003 Q3-004 GUI: MISC members connected to other MISC members may not show on the correct positions. MISC members almost parallel to the y-plane may have different "from" and "to" ends in the old and new programs as a result of different round-off in the two programs. New program modified to match the old program.
02/12/2004 3.0.002 Q3-003 GUI: Need to allow using hardware keys on servers. Completed. See Tools/Options on the main menu. Options are provided to the users to specify the location of the hardware key: (1) Local; (2) Either local or any attached server; or (3) Specified server name.
02/03/2004 3.0.001 Q3-002 GUI: Application should not start unless complete installation is found on the system. Done.
02/03/2004 3.0.001 Q3-001 GUI: Some beams are not plotted at the correct locations on the Graphics for the "Analysis Model". Error fixed in graphics. Problems showed for sloped members when a "SLOP" command precedes the "LOAD" command. Locations of members on the "Construction Model" graphics were OK.
01/01/2004 3.0.051 Q3-092 GUI: Program hangs up when closing the measure dialog. Fixed programming logic.
03/08/2001 3.0.179 Q3-359 GUI: Change the default for displaying reaction to 'NO' Done.
 

Corrections Prior to Version 3.0.0

Resolution Version Date Fixed QC/QA Number Problem Description Resolution
2.2.3 09/27/2003 Q312 Overstress & Code Check reports display non-text characters if a replacement section is not found. This causes problems with some text editors Fixed problem by displaying 'NO SECTION FOUND.'
2.2.3 08/19/2003 Q311 MISC/QJNT Problem -- GEOM Program Halts if a MISC member is connected from a lower floor to a beam on upper floor at a point where a QJNT exists. Fixed the problem.
2.2.3 08/18/2003 Q310 GEOM Problem: String/Phantom Loads with zero loads and spanning more than one bay may not create the proper beams Fixed the problem
2.2.3 08/11/2003 Q309 Foundation: Update the Help File with the changes done by Jeff. Done
2.2.3 05/27/2003 Q308 Foundation: Program runs into an infinite loop when analyzing pile foundations. The loop happened during calculation of reinforcement diameter to satisfy development length. Program fixed to issue a warning that hooks may be needed.
2.2.3 05/20/2003 Q307 STAAD: Code check output may not display correct reactions for files containing CEND commands, running under STAAD. Member forces, stresses and displacements should be OK. Fixed problem
2.2.3 03/28/2003 Q306 PDMS, DETAIL: Output in PDMS AND DETAILING for columns is not sorted. Sort records by floors and column names. Completed as specified.
2.2.3 03/13/2003 Q305 Geometry: Field 8 of MISC command did not accept Block letter for Elevation Name. Fixed problem. Elevation name in field 8 can be entered as EL00B (The Block letter is the fifth character.
2.2.2 03/12/2003 Q304 Issue new updated version 2.2.2. All changes up to date has been grouped and issued as a patch '220to222update.exe'
2.2.2 03/12/2003 Q303 Code Check: Check shear for pipe and tube sections. Tube (TS) sections are checked using the W-section equations for web. Allowable shear stress for pipe section is taken as 0.4 Fy. If D/t exceeds 100, a warning message is printed.
2.2.2 03/11/2003 Q302 Code Check: Error is displayed for pipe sections under compression (error -- FE is zero). FE and effective KL/r will not be calculated for pipe and tube sections. Check is bypassed for these sections.
2.2.2 03/05/2003 Q301 Geometry: Error is produced "Maximum number of joints exceeded", when connecting too many MISC members between floors (above 3999). Fixed problem by increasing limit.
2.2.2 01/06/2003 Q300 Displacement Report: Program halts and gives error message if number of grid points exceeds 10,000. Increased limit to 20,000.
2.2.2 01/02/2003 Q299 Code Checking: Run stops if a beam supports more than 41 other beams. Increased the limit to 51 and issued a fix.
2.2.2 12/15/2002 Q298 User Table: User Steel table program fails without error message, if 'Number of Sections' does not follow Units for USERT sections. Corrected problem with printing the error message (programming error).
2.2.1 11/15/2002 Q297 Geometry: MISC members connected between floors were not assigned as vertical brace, if distance between floors was less than 2.0 ft. This caused reaction errors in (Geometry & Loading 2 --DESI). Corrected.
2.2.1 10/27/2002 Q296 GEOM: Line numbers in output file are printed as **** if input file include more than 9999 lines. Fixed the Geom.exe program to print line numbers in 5 columns.
2.2.1 10/27/2002 Q295 GEOM: Hidden characters in the GEOM file cause problems running the program. Fixed the program to ignore non-text characters in the GEOM.DAT file.
2.2.1 06/05/2002 Q294 Steel Tables: PDMS (Michelle) requested information for NA coordinates for non-symmetric sections of the MAPLE table. Modified the STABLES program to add the requested information to the .PDM file. Reran the program for the MAPLE table and sent the 'maple.pdm' file to Michelle
2.2.1 05/15/2002 Q293 User Steel Table: Using MAPLE table in the user steel table, does not use the correct sectional properties. MAPLE's Input file data 'shape.dat' included unit as 'STD' instead of 'METR'. Corrected value and issued fix Q293.exe
2.2.1 05/15/2002 Q292 Steel Tables: When creating steel tables, a file '.pdm' is created to transfer table information to pdms programmers. We need to eliminate duplicated sections used in SCADS as a WB once and WC another time. Modified translation program to eliminate duplication. Ran program for MAPLE table and emailed the file to Michelle Robinson.
2.2.1 04/22/2002 Q291 PDMS: File created for PDMS does not run on the PDMS system. The translator printed negative rotation angles greater than 99.999 as ******** in the PDMS file. Problem fixed and issued "Q291.exe" fix.
2.2.1 04/19/2002 Q290 Foundation: Program terminates abnormally for some columns with uplift, referring to a negative square root value. Fixed the problem and issued fix Q290.exe for testing.
2.2.1 04/12/2002 Q289 Code Check: Code Check module (SCOLD) produces access violation error, if number of overstressed members exceeds 551. Increased limit to 5000.
2.2.1 03/19/2002 Q286 Error from DESI stating *LHANG ERROR ON FLOOR EL40 ** SEVERE SYSTEM ERROR.
NUMBER OF FLOORS INVOLVED IN HANGERS WHICH MUST BE
PREDESIGNED EXCEEDS 20. NFPRE= 21
Fixed code to allow hangers to go through a maximum of 40 floors instead of 20. This error would only have effect on pre-sizing of members supporting hangers.
2.2.1 01/17/2002 Q285 DETAIL: Horizontal skewed beams created by MISC commands do not report the correct maximum end-moments in the DETAIL(SDS/2) file. The DETAIL program considers horizontal MISC members as horizontal bracing, checking only axial forces. Changed the computer program to handle these members as beams if shear reactions or end-moments exist.
2.2.1 01/04/2002 Q284 PDMS & DETAL: Members added as Posts in Refiner produce errors when running PDMS and DETAIL. Fixed. Refiner did not place the 'From' floor in the correct place in the "STEL.AUX' file.
2.2.1 11/02/2001 Q080 Analysis: Send section names to the analysis program (e.g., to GT-STRUDL) rather than prismatic properties. Completed only for the AMSTL table and GT-STRUDL input.
2.2.1 10/16/2001 Q282 STAAD: The following error is received 'CHANGE unexpected command' for tension-only analysis in STAAD. Fixed problem and issued correction with 'Fix Q281.exe'.
2.2.1 10/16/2001 Q281 STAAD: The following error stops STAAD from running 'FOR-LOAD STAPLE command before other FOR commands' This problem shows in Version 2001 Build 1005 Patch 18. Fixed problem and issued 'Fix Q281.exe' on the web.
2.2.1 10/16/2001 Q280 Geometry: Wrong values are used for Fy and Fu (from BFY, BFU, CFY, CFU commands) when input units are specified as 'METRIC' or 'SI' Fixed problem and issued 'Fix Q280.exe' on the web.
2.2.1 10/11/2001 Q278 Analysis: Temperature load cases are not generated for GT-STRUDL analysis. Partially fixed a related 'Code Check' problem, and issued Fix 'Q278.exe' in the web.
2.2.1 09/27/2001 Q277 PreSTATIC "CONNECT" command needs to be explained clearer (Give examples). Completed as suggested. Issued fix Q277.exe
2.2.1 08/15/2001 Q276 Drafting: Column Schedule does not show correct horizontal Wind/Seismic Loads Fixed the problem and issued a patch (Q276.exe). Versions prior to this fix were not reporting the shear/moment values for columns with exactly zero axial-loads.
2.2.0 05/25/2001 Q274 CODE CHECK: GEOM and PreSTATIC File dates do not show, at top of report, under Windows 2000. Modified code to display the information for all windows systems.
2.2.0 05/25/2001 Q272 Include new version of PD-STRUDL and issue version 2.2.0.
Update Web to reflect changes.
Completed. Tested and adjusted system for Various Operating Systems (95/98/NT/2000)
2.1.3 05/23/2001 Q247 Geometry: QJNT after MISC command causes the program to halt with an error message indicating "Abnormal termination" Fixed earlier. Could not reproduce the error.
2.1.3 05/22/2001 Q243 HELP: PreAnalysis help for SCOM, Note 7 states that WF (wind factor) = 0 is used as default. This should be 0.33 Modified Note 7 and regenerated the help and 'pdf' files.
2.1.3 05/16/2001 Q271 Analysis: Install and test StaadPro 2001. Completed. Changed the default Staad folder to SPRO2001. Users under Windows 95/98/ME should download a patch from the STAAD web site.
2.1.3 05/16/2001 Q270 Development: Move the development environment from Windows 98 to Windows 2000. Completed. This change should not affect the user.
2.1.3 05/16/2001 Q269 GEOM: PIN command does not work for top of the hanger. A few years ago, the default for Hanger top was changed from pinned to fixed. FIX was used earlier to change the default. PIN should now allow changing the Fix default. Fixed the problem. To pin a hanger top now, add a PIN command at the HANG command floor.
2.1.3 05/09/2001 Q268 Help: Correct the help-text for 'GEOM PIN' command. Cantilever end can be pinned by listing the cantilever (not with PIN ALL). Done. Modified and regenerated the GEOM help and PDF files.
2.1.3 05/07/2001 Q267 User Interface: Deleting a project, when the spreadsheet-input page is open, produces an error message. Also, file delete with windows 2000 produced an error. Fixed problems.
2.1.3 05/07/2001 Q266 User Interface: "Save as" changes related to Q264 did not work exactly as intended. Fixed problems.
2.1.1 04/30/2001 Q265 User Interface: Allow user to activate STAAD from the 'Analysis-Review' Bar Menu option. Activated the option. Added a message to remind the user to go to the Post-processing mode of STAAD. The message can be turned off for later runs.
2.1.1 04/24/2001 Q264 User Interface: Allow user to change the buildings folder (SCADS) from the File Open, File New, and File Save As forms. Completed as suggested. "Files Location" button has been added to the three forms. Clicking the button activates the "Files Location" dialog to change the SCADS building folder.
2.1.0 03/30/2001 Q212 Analysis: Current "Fortran" routines are compiled using "WATCOM" compiler. This compiler has been discontinued. We need to recompile all "Fortran" programs using "Visual Fortran" Complier". Fix and test as needed. Project completed. Thirty-five (35) Fortran programs have been generated using Visual Fortran Compiler. Source files consist of over 1,800 routines. Needed modifications were made. Steel tables (binary-format data files) have been regenerated. System has extensively been tested. Version 2.1.0 is ready for release as soon as the new PD-STRUDL version is received and included.
2.1.0 03/29/2001 Q262 Analysis: new STAAD Translator version does run for tension only members. Fixed the problem in the code.
2.1.0 03/29/2001 Q260 CODE CHECK: For British code, if axial force is not zero and axial interaction ratio is not used (Section 4.8.3.3.2) print N/A instead of a zero value for the AXIR in the report. Completed as suggested.
2.1.0 03/09/2001 Q250 User Interface: 'Analysis Review' bar menu item added under Q241 should only show one analysis system (Current selected analysis program). Also, File location for selected analysis program should be queried when selecting the analysis program. Completed as suggested.
2.0.9 02/20/2001 Q258 Geometry: System does not directly catch problems with connecting X/Y beams to top of SUPP column. Fixed problem by issuing an error message and ignoring the beam.
2.0.9 02/20/2001 Q257 Help: PDELTA command in the Analysis Help file is not linked to the correct page. PDS command not listed on the contents page, and is not linked through the F1 key. Fixed problems with this Help file. Also fixed similar problems with Frequency help file.
2.0.9 02/13/2001 Q249 Develop a proposal and plan to create/modify SCADS input graphically, instead of current text mode. Completed and submitted.
2.0.9 02/02/2001 Q256 General: Test and issue Version 2.0.9 for testing. Tested and issued version 2.0.9.
2.0.9 01/31/2001 Q255 PDMS: PDMS data file contains FP and TP data lines describing member end connections. Removing these lines may reduce time taken by PDMS to create the model. Added an option buttons to specify a 'Connected' or 'Un-connected' model. See the Construction-Model Run Menu. Last selected choice is remembered for each building. Default is 'Connected Model'
2.0.8 01/29/2001 Q253 GTS Translator: Include PDELTA analysis if DANNAS.DAT file contains 'PARAM,PDELTA,YES' line -- not when GEOM is specifying the LRFD as the design code. Completed as suggested.
2.0.8 01/28/2001 Q254 Staad Translator: Include new version of nas2std developed by Jeff Stokes for visual C++. Remove previous Borland's version and test new version. Added the modified beta angle computation routine, developed under Q246.
2.0.8 01/26/2001 Q252 STAAD Translator: Include PDELTA analysis if DANNAS.DAT file contains 'PARAM,PDELTA,YES' line -- not when GEOM is specifying the LRFD as the design code. Completed as suggested.
2.0.8 01/26/2001 Q251 User Interface: Under Tools/Options, move file locations for analysis programs to the "Analysis" page where analysis programs are selected. Completed as suggested.
2.0.8 01/26/2001 Q244 USER INTERFACE: Starting STAAD from 'Static Structural Analysis" (not from Cycles option) does not place user in building directory when Staad starts. Added file name to the command in the batch file, to directly open the file.
2.0.7 12/11/2000 Q246 STAAD: Beta angle for one member is 180 degrees instead of zero in the STAAD file. Round off in the SCADS coordinates data caused this error. Fixed translator problem.
2.0.7 11/28/2000 Q242 STEEL TABLE: Disable automatic selection of S, M, HP and WWF sections from the MAPLE (Canadian) steel table. SCADS should only pick W sections. Changed the selection code for the I-shaped sections other than W type.
2.0.7 11/22/2000 Q241 User Interface: Add post processing graphics capabilities of PD-STRUDL A new "Menu Bar" option (Analysis-Review) has been added. Under this option, other selections have been added such ass PD-STRUDL Static, PD-STRUDL Frequency, GT-STRUDL STATIC, etc.
2.0.6 11/16/2000 Q240 STEEL TABLES: STAAD reports errors when using LARGC steel table. Properties numbers were repeated for column and beam sections, causing the problem. Sections property numbers needed to be updated. The problem also existed in the following tables: ASSUI, BMXID, CMIXD and INDIA. All tables have been fixed.
2.0.6 10/27/2000 Q239 User Interface: Download and install Visual Basic Service Pack4. Recompile winscads.exe Done.
2.0.5 10/23/2000 Q229 User Interface: Use upper case only for all controls in the "Open", "Save As" and "New" dialogs Done.
2.0.5 10/21/2000 Q237 GEOM help examples include errors - See Jennifer Marcon email. All examples were reviewed and errors were fixed. Changes made to examples under BLOD; BLOK; CEND; COL/XCOD..; CEND; DEL; DMIN; ELEV; FPM; HORZ; KFAC; Line Load; Equipment on 2 supports; Circular Configuration Equipment Loads; Area Load; DIAG; NBRA; POST; RCOL; SKIP, UBL and WIND.
2.0.5 10/19/2000 Q236 HELP: ends of XBRA members connected to columns after SLOP command stay on the un-sloped floor level. Fix Help document to indicate this fact. The following tip was added to the SLOP command help. "XBRA & KBRA members should be connected to actual elevations. If not possible, Use MISC members instead." Similar statements were added to the XBRA & KBRA help
2.0.5 10/18/2000 Q232 Help: Some Geometry Help Examples show '*' instead of fractions (in Graphics) Two figures were corrected (Example 1 for Openings and Example 1 for DAIG command). CQUD spreadsheet example was also corrected.
2.0.5 10/18/2000 Q231 User Interface: When using Save As dialog, provide the user the option to open the new saved building. Added a button to open the copied file if needed.
2.0.5 10/17/2000 Q234 GTSTRUDL: Post-processing FOR GT-STRUDL Version 25 does not complete successfully. GTS changed year format from two digits to 4 digits causing post processing to terminate. Problem fixed.
2.0.5 10/17/2000 Q228 Help: F1 key does not open the correct page when if no space character exist between field 1 and 2. Fixed problem
2.0.5 10/12/2000 Q233 GEOM: Phantom load applied at columns produces an error message "Divide by zero" Corrected programming error.
2.0.5 09/28/2000 Q188 PreAnalysis: Change the MISC member to CROD (truss) element, unless end conditions are changed in PreAnalysis input. Currently all non-horizontal MISC members are treated as 'truss' elements. Since Horizontal MISC members can be loaded (similar to beams). Added another Q number (Q227) to allow user to indicate that the MISC member should be treated as truss element.
2.0.5 09/28/2000 Q142 Geometry: Load on a non-orthogonal MISC is not passed to the analysis Load is passed to analysis correctly. However, the graphical sketch program was not showing the load properly. Fixed the problem.
2.0.5 09/26/2000 Q184 Code Check: Verify and fix the stress check for SP & TS shapes under ASD9 code. Shear stress is not checked for these shapes. SP section is checked as TS (See ASD9 Section F3). This may overestimate actual stress in case of bi-axial bending. A warning message is now issued indicating that shear is not checked for SP & TS sections.
2.0.5 09/25/2000 Q226 PDMS: PDMS run did not complete with error stating 'bad character in input' Error occurs as a result of a limit set in the Sketch program of 2000 members. Size increased to 8000.
2.0.5 09/22/2000 Q225 HELP - FOUNDATIONS: On contents page add link to "default values- spread footings" and default values- pile fdns". Place these sections after "Warning Messages". Move values to these sections.
The "Running independently" page should explain that default unit is taken from the geom "Output Unit" command.
Help & PDF files have been modified as suggested.
2.0.5 09/21/2000 Q161 Detailing: Add documentation to the help file to show which member forces are transferred in the Neutral file. A new section entitled "Member End Loads" has been added to the "Detailing" help and pdf files.
2.0.5 09/21/2000 Q140 Help: Add 'expected' order of GEOM commands to the help file. Added section "GEOM Commands in Order of Usage" to the help & pdf files
2.0.5 09/21/2000 Q136 DETAIL: Shape type 'C ' is recorded as 'WB' -- See AA Card. Check for other types. Fixed programming logic. A recent fix caused the problem.
2.0.5 09/20/2000 Q134 Drafting: No prompt for backup on NT. 'CHOICE' DOS command is not valid for NT. Removed the DOS command. Added a 'backup' option with the Graphical interface when selecting files to update. Two backup copies are saved when requested.
2.0.5 09/19/2000 Q187 GT Translator: Multiple joint load cards produce warning message by GT-STRUDL. Add joint loads to eliminate warning. Modified translator to combine multiple joint loads. Also joint loads are now sorted by joint number.
2.0.5 09/14/2000 Q182 STAAD: StaadPro issues warnings about changing loads applied at ends of members to joint loads to avoid the warning.messages. Modified the program to Move member loads applied at member ends by .001 (ft or m) to avoid the warning.
2.0.5 09/05/2000 Q223 STAAD: Units command is not correct if the code is BSI and units is not SI. Corrected programming error.
2.0.4 08/29/2000 Q222 ANALYSIS: GT-STRDUL produces warning messages that load is beyond member length and then ignores the load. This is important to correct if the load is a concentrated type applied at the end of the member. Load length was truncated at 2 decimal digits. The problem is produced if the load length was exactly 2.45 (for example) and GTSTRUDL calculates the member length as 2.449999. Fixed the logic to truncate the load length at 3 decimal digits after subtracting .001.
2.0.4 08/24/2000 Q218 User Interface: Add hot key for insert remark and remove remark Feature added. Use Ctrl-R and Ctrl-U to mark and unmark lines when using the Spreadsheet input format.
2.0.4 08/24/2000 Q214 AddSize: In GEOM data, if a member size is provided twice with a field-3 value of "U" in the first card, and blank in the second, Code-Check considers the section as initial size (U) and creates another size in the ADDSIZE file. Processing of a size card following "Un-designed" size card (letter U in field 3) has been changed from error to warning. Also, the "Un-designed" card is now ignored instead of the other one.
2.0.3 08/18/2000 Q221 GT-STRUDL: Maximum displacement joint may not be reported correctly if some joints are skipped in the data file. This may happen when using exclude command in PreSTATIC input. Fixed GTS translator to handle this situation.
2.0.3 08/17/2000 Q217 STAAD: Run does not complete if some joints are skipped in the data file. This may happen when using exclude command in PreSTATIC input. Fixed STAAD translator to handle this situation.
2.0.3 08/16/2000 Q220 STAAD & GTS Translators: Non-horizontal members in the vertical plane containing the x-axis and rotated 270 degrees are only rotated 90 degrees. Fixed programming error.
2.0.3 08/16/2000 Q219 STAAD Translator: SCADS-to-STAAD translator does not run when a "DIAG" command is added in the PreANALYSIS input. Fixed program code. (DIAG line precede the SYS in scold.dat file)
2.0.2 07/21/2000 Q213 STAAD: LRFD implementation fix (Q209) created lines exceeding 79 characters in width. Fixed programming error.
2.0.2 07/18/2000 Q042 Code Check: Customize Output Reports Removed. Similar to Q164.
2.0.1 07/12/2000 Q211 Help: Convert Help (Users Manuals) to Acrobat's PDF format. Done. All documents are located under \WinSCADS\PDF\ folder.
2.0.1 07/11/2000 Q190 Code Check: Document current LRFD implementation and prepare a plan for needed changes. Reviewed implementation documents by Helga & Craig. Fixed GT-STRUDL and STAAD translator to account for P-Delta effects (SEE Q208 & Q209). A new Q/A item (Q210) added for needed documentation.
2.0.1 07/10/2000 Q209 STAAD: For LRFD analysis, change the STAAD commands from 'LOAD COMBINATIONS' to 'LOADING & REPEAT' commands. Also, change the analysis type from 'Linear' to PDELTA' to account for PD effects. Modified as suggested.
2.0.1 07/10/2000 Q208 GTS: For LRFD analysis, change the GT-STRUDL commands from 'CREATE LOAD COMBINATIONS' to 'FORM LOAD' commands. And change the analysis type from 'Linear' to 'Geometric Nonlinear' to account for PD effects. Modified as suggested. Note: 'CREATE LOAD COMBINATIONS' combines linearly results of the independent load cases. 'FORM LOAD' creates a new load case from the independent load cases that can be analyzed later.
2.0.1 07/10/2000 Q207 User Interface: Run Update program automatically if it is the first time to run one of the "Construction Model" programs. Modified 'Run Construction Applications' Dialog to enforce running the 'UPDATE' program to create files for the first time.
2.0.1 06/19/2000 Q206 Code Check: ' DIAG = 58 ' in PreSTATIC input stops Code Check program from running Fixed programming error.
2.0.0 06/01/2000 Q205 Analysis: Replace current (DOS) version of PD-STRUDL with the new (Windows) version (ver. 0400). Done as suggested.
2.0.0 06/01/2000 Q204 Installation: Use "Wise" Installation software to install WinSCADS. Changed installation procedure from Winzip & VB setup to "Wise" system.
2.0.0 05/31/2000 Q203 PreAnalysis: Excluding loaded members create invalid load cards with member number 0. Eliminated load card and issued a warning. Also, added a note under EXCLUDE command in the help file.
2.0.0 05/29/2000 Q202 User Interface: File-Locations browse buttons should be enabled unless N/A is checked. Also, if WinSCADS is started from a different folder, change the location of PD-STRUDL accordingly. Changed as suggested
2.0.0 05/24/2000 Q199 User Interface: Remove tool-bar-buttons from child (input/output) windows that also appear on Main window tool bar. Remove caption text (For example Save, Print, Copy..) from the child window tool-bar. Leave text on Main window. Implemented as suggested.
2.0.0 05/24/2000 Q104 User Interface: Find Dialog should be modal for WinSCADS only (not system). Also, when Find Dialog gains focus, the focus should be given to the search text. Fixed as suggested.
2.0.0 05/22/2000 Q198 PLOT: Running PLOT for Natural Frequency results in "memory allocation error". fixed programming error in User Interface.
2.0.0 05/19/2000 Q197 Frequency Analysis: Remove self weight cards (subcase 1002) from dynamic file. There is no need for these cards. Completed as suggested.
1.5.0 05/18/2000 Q196 User Interface: Window titles for Frequency Analysis and Response Spectrum Analysis were not correct. Fixed
1.5.0 05/15/2000 Q195 User Interface: Remove from Tools menu the option for "Prepare for PD-STRUDL DOS Run". The new PD-STRUDL version runs under window only. Done as suggested.
1.5.0 05/15/2000 Q193 Analysis: Move PDTRAN.EXE (PD-STRUDL translator file from the STRDUL-program folder to WinSCADS folder. (Translator is part of WinSCADS and not the STRUDL program). Moved PDTRAN.EXE to scadsp/strudl/yexe folder with all other translators
1.5.0 05/10/2000 Q192 User Interface: Print current date on the error message that license has expired (Some system settings may result in unexpected data for current date). Done as suggested.
1.4.14 05/11/2000 Q163 Code Check: Beam End forces needs to be sorted by Member number and floor (not analysis number). Floor names need to be added in report. Added floor and Block ID to the GEOM name.
1.4.11 05/03/2000 Q191 Drafting: Dimension lines are changing style on some drawings. Text color should be set to zero. Dimension lines used the latest created line. Program fixed to set the style to zero and text color to zero instead of 4.
1.4.10 05/02/2000 Q185 PreAnalysis: Self weight for CROD (truss) elements is missing. Also W sections bracing members are created as CBAR and should be changed to CROD similar to all other bracing member types. Completed as suggested. The database files were re-created to add files for the W-ROD element properties (WPROD.NAS). USERT program was also fixed.
1.4.10 05/02/2000 Q139 Geometry: Divide by zero error is displayed if a SLOP command is issued after a MISC command. See file 9999/all/test/jef5 Done according to Pravin
1.4.10 04/20/2000 Q183 STEEL TABLES: STRUDL produces errors when using some SP sections as beams or columns. Error happened if section is used as a beam or column. The IY value was not transferred to the analysis file causing instability. Problem now fixed. Since Bending check of pipe sections was never used, another QC item (Q184) is added to carry out the verification process.
1.4.10 04/18/2000 Q179 PreDANA: Wrong model is created for cantilevers to the left or below the corner (0,0) column. Problem in Q154 was not solved. Fixed another programming error and issued a fix.
1.4.10 04/18/2000 Q178 STAAD: For some files, StaadPro produced error while reading input file. StaadPro has a problem when starting and opening the file in one command lien. Modified batch file to only start STAAD and let the user open the file. Issued a fix on the web site.
1.4.10 04/17/2000 Q177 HELP: Users could not access Geometry Help file from the 'Contents' Tab of the Help option. Fixed Help Contents file (winscads.cnt) and published a fix.
1.4.09 04/12/2000 Q173 Help: System creates more than one help window if the Help option 'Keep on Top' is activated. Fixed programming error.
1.4.09 04/12/2000 Q171 Support: Establish WinSCADS.COM web site. Registered and established WinSCADS.COM web site. Documents moved from roufaiel.com/WinSCADS to new site. 'Help on the Web' menu item now points to new site.
1.4.09 04/11/2000 Q172 Graphics: Microstation J files do not close automatically. User has to press OK. MSJ has a problem with the command to close with prompting the user. Modified program to close MS using a different procedure.
1.4.08 04/07/2000 Q168 Analysis: Install StaadPro and test operations and results. Done as suggested.
1.4.08 04/07/2000 Q088 Analysis: Add capabilities to use the STADD-PRO as the analysis program for STATIC, NATURAL FREQ and RSA Completed Static Analysis without the "tension-only) concept. Work is continuing
1.4.08 04/06/2000 Q170 Analysis: Users need instructions on how to setup WinSCADS with various supported analysis programs. See WinSCADS Help Contents. We added a new topic (Analysis Program Setup). The complete document is under WiSCADS/docs/engines.doc.
1.4.08 04/05/2000 Q169 Analysis: Copying building to another folder does not change the building name components (Proj/Site/DA/Bldg) at beginning of 'Code Check' (scold) output. Fixed. 'rundana.dat' file contains the information reported in 'Code Check' header. File is now updated by the UI when building is opened in WinSCADS.
1.4.08 04/04/2000 Q167 PreAnalysis: Allow the user to do GT STRUDL run without bandwidth reduction -- This is needed for buildings consisting of more than one structure. Added a PreAnalysis Command
GTS WITHOUT REDUCE BAND. Also updated users manual.
1.4.08 04/03/2000 Q165 UI: Allow user to select different name for the STAAD executable (for example (STAAD.EXE or STAADPRO.EXE). Modified as suggested.
1.4.08 04/03/2000 Q115 Graphics: Compile and test Graphics programs under MicroStationJ. Make changes needed for implementation. Made minor changes to get graphics programs to work with MSJ. User Interface Dialog box 'Update Graphics Programs' has been changed to allow user to switch between the SE and J versions.
1.4.08 03/31/2000 Q159 Detailing: Compression forces are not reported for some members in the Neutral file. Fixed a programming error.
1.4.08 03/30/2000 Q160 Detailing: Neutral file is not reporting same member force at the two ends of bracing members. Bracing pair ends were assigned group numbers to report same forces. Removed this grouping concept to report actual member forces. This fixed the problem.
1.4.08 03/04/2000 Q166 PreSTATIC: NASTRAN.DAT file contains the DA field on an ID card. The DA is printed as **** if we use a non-numeric DA. Fixed.
1.4.07 03/28/2000 Q158 Detailing: Prevent creation of SDS/2 file for Metric units. SDS/2 does not use MTON for metric units. Issue a message to the user to change the OUTPUT command in GEOM to SI and re-run the complete analysis. Fix the 'Help' file. Modified as suggested.
1.4.07 03/28/2000 Q157 User Interface: Change default number of Analysis-Code Check, on the Run Dialog, from 2 to 1. Changed as suggested.
1.4.07 03/28/2000 Q150 PreAnalaysis: Allow the user to specify the exclusion of the FINISH command from the GT-STRUDL input file. Added new command 'GTS OMIT FINISH' in PreSTATIC and Frequency input files. Also amended the Help files.
1.4.07 03/28/2000 Q145 SKETCHES: Long section names are not shown complete. Sketches was showing only first 12 characters of section names. Fixed to show all 18 characters.
1.4.06 03/24/2000 Q156 Plot: Start the PLOT program directly when Icon is clicked (Nastran Static file is selected automatically). Provide the other choices through the menu item for 'Graphics'. Completed as planned.
1.4.06 03/24/2000 Q151 Frequency: Mass value is not calculated as provided in the static analysis calculations in some buildings. See 9999/all/test/jef1 building. Self weight is not automatically included. Added a button on the 'Analysis' (A.A.) dialog to warn user about Analysis Defaults.
1.4.04 03/07/2000 Q154 PreDANA: Wrong model is created for cantilevers to the left or below the corner (0,0) column Fixed Predana.exe -- Programming error.
1.4.04 03/06/2000 Q153 Displacement Report: Unit specified for rotation is 'Degrees' and not 'Radians' as reported under report title. Fixed program.
1.4.04 02/16/2000 Q152 Sketch: When running Sketch, the user receives error message "MDL memory access error in line 2108 of LOAD2DGN". Fixed programming error in module load2dgn.mc
1.4.04 01/12/2000 Q149 Analysis: Metric and SI units labels are reversed in the GT-STRUDL input file. Fixed NAS2GTS program.
1.4.04 01/06/2000 Q147 PDMS: Building name or DA shorter than 4 characters causes PDMS error. Modified U.I. To enforce 4-chrs names for the Building and DA fields. Also, fixed the SACDS-2-PDMS module to create the correct header line.
1.4.04 01/05/2000 Q148 PreSTATIC: in GT-STRUDL generated file, members are not rotated if the rotation is not 90,180 or 270 degrees. Fixed nas2gts program.
1.4.04 01/03/2000 Q146 UI: Set Window to normal if it was minimized before exiting WinSCADS. Fixed.
1.4.04 01/03/2000 Q124 Help: Develop and implement the online help file for the Natural Frequency Analysis Developed and implemented.
 

Home ] News ] Highlights ] FAQ ] [ Prior Updates ] Updates ] Download ]
WinSCADS and SCADS are software systems developed by the Civil Engineering Systems of  DuPont Engineering, E. I. du Pont de Nemours and Company.  Technical Support is provided by Roufaiel Associates.
All other products mentioned are registered trademarks or trademarks of their respective companies.
Questions or problems regarding this web site should be directed to support@WinSCADS.com.
Last modified: Tuesday March 23, 2010.