WinSCADS Correction
Date Fixed QC/QA Number Problem Description Resolution Resolution Version
11/15/2011 Q4-341 GUI: Field 12 (Maximum depth) on load command is not checked for correctness. Added checking routine for field 12 (maximum depth) of the LOAD command. 4.9.0.1
11/15/2011 Q4-342 GUI: Switching between 2 monitors and 1 monitor may cause some windows to disappear. Corrected the problem by bringing the dialog to the first monitor if left top corner is out of current screen limits. 4.9.0.1
11/16/2011 Q4-343 GUI: User interface displayed error when using SI unit for USER TABLE file. Corrected problem. 4.9.0.1
11/17/2011 Q4-344 User Table: SL and LL sections produce steel table errors. Corrected programming errors 4.9.0.1

WinSCADS and SCADS are software systems developed by the Civil Engineering Systems of  DuPont Engineering, E. I. du Pont de Nemours and Company.  Technical Support is provided by Roufaiel Associates.
All other products mentioned are registered trademarks or trademarks of their respective companies.
Questions or problems regarding this web site should be directed to support@WinSCADS.com.